Purpose. To evaluate surgical outcomes of ipsilateral femoral neck and shaft fractures. Methods. Between April 1997 and September 2004, 29 men and 8 women (mean age, 37 years) underwent fixation of femoral neck and shaft fractures using a dynamic compression plate plus a dynamic hip screw or screws. There were 30 femoral neck and 7 pertrochanteric fractures. Functional results were assessed according to the Friedman and Wyman classification. Results. The mean follow-up period was 49 months. Of the femoral neck fractures, 34 united in a mean of 4 months; 33 of them healed anatomically and one with a 6º varus angulation. No osteonecrosis of the femoral head was noted. Of the femoral shaft fractures, 32 united in a mean of 6 months, 5 were non-unions (2 persisted even after revision surgery). Seven patients developed infections (5 superficial and 2 deep), which resolved with debridement and antibiotic treatment. Surgery 2008;16(1):35-8 shaft fractures is reliable in achieving bone union with few complications.
Journal of Orthopaedic
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.