Patients with vascular diseases present with a long medical history which makes for complex and confusing medical records. Electronic record systems have a large storage capacity and high information processing capabilities, and may therefore improve the quality and reliability of prospective clinical studies. In the present study, a theoretical framework for clinical data collection in chronic visceral ischemia was created containing 5706 items, organized into six major categories: medical history, physical examination, laboratory testing, diagnosis, treatment and outcome. The database was used to construct an electronic data collection protocol, which was uploaded into the Integrated Electronic Protocol System (Sistema Integrado de Protocolos Eletrônicos, SINPE©) and then used to perform retrospective collection and analysis of clinical data from 10 patients using the SINPE© analysis module.
Resumo Contexto Mostra-se relevante a elucidação da influência da densidade de energia endovenosa linear (linear endovenous energy density, LEED) média no sucesso do tratamento da insuficiência venosa crônica por termoablação endovenosa a laser visando diminuir a morbidade desse método. Objetivos Avaliar a influência da LEED média na prevalência de fechamento das safenas após 30 dias do procedimento. Métodos Foram analisados 153 membros inferiores de 118 pacientes de um hospital referência, submetidos a termoablação com laser endovenoso 1470 nm sob anestesia local para o tratamento de insuficiência venosa crônica. Foi calculada a LEED média dos pacientes tratados para determinar se foi necessária uma energia maior que a média para o sucesso do tratamento. Resultados Dos 153 membros inferiores submetidos ao tratamento, houve diferença significativa (p = 0,021) no fechamento da junção safeno-femoral relacionada à LEED média utilizada acima do joelho. Por outro lado, no segmento de coxa não houve diferença significativa. Conclusões A LEED acima da média de 70,57 J/cm apresentou um índice maior de fechamento na junção safeno-femoral. Porém, no segmento de coxa, a densidade não influenciou o resultado, demonstrando que uma energia mais alta do que 70,57 J/cm tende a não ser necessária para o tratamento desse segmento.
Background Endovascular treatment in trauma is a promising strategy to reduce perioperative morbidity and mortality. We report the case of a gunshot wound causing an initially undiagnosed subclavian artery injury, with delayed progression to a complex, difficult-to-manage arteriovenous (AV) fistula. Placement of an encapsulated endovascular stent graft resolved the primary lesion, but persistent cervical arteriovenous communications were only repaired after multiple, sequential embolization procedures. Report A 25-year-old male sustained a gunshot wound to the right neck. Initial treatment failed to identify any vascular injury, and the patient was discharged. Three weeks later, he presented to our facility with headache and a palpable right-sided cervical thrill. Arteriography showed contrast extravasation from the right subclavian artery and an AV fistula with the ipsilateral internal jugular vein. The arterial injury was repaired with an encapsulated stent graft, but residual contrast leak persisted on follow-up angiography. Three months after the first intervention, cervical thrill was still present; a right vertebral–right internal jugular AV fistula was identified and repaired by distal coil embolization. One month later, persistent symptoms prompted repeat arteriography, which again identified contrast extravasation, now involving the thyrocervical trunk. Selective thyrocervical embolization was ultimately successful, with resolution of symptoms and no further evidence of contrast leak. Conclusion Delayed management of neck trauma can be challenging due to neovascularization, which hinders open repair in this delicate region. Post-traumatic arteriovenous fistulas are thus a particularly fearsome complication, and can be very difficult to approach; as in our patient, multiple interventions may be required. This case highlights the importance of detecting vascular trauma as early as possible, as a delay in diagnosis can hinder treatment and eventuate challenging late complications. Further studies are needed to demonstrate the long-term benefits of endovascular management of complex vascular injuries of the neck region.
Resumo Contexto Na insuficiência venosa crônica (IVC), a veia safena parva (VSP) é afetada em 15% dos casos. A cirurgia convencional é a técnica padrão para o tratamento da insuficiência da VSP, sendo a lesão no nervo sural uma complicação bastante temida. O tratamento de termoablação com endolaser tende a ser um método cirúrgico que diminui complicações da terapia cirúrgica da IVC. Objetivos Avaliar os pacientes com IVC submetidos à terapia por endolaser da VSP ao menos 30 dias após o procedimento. Métodos Foram analisados 54 membros inferiores de 46 pacientes submetidos à terapia por endolaser 1470 nm, sob anestesia local, para o tratamento da IVC em um hospital terciário. Os pacientes foram avaliados no período pré-operatório, intraoperatório e pós-operatório de 30 dias, através da clínica, exame físico e achados ecográficos. Resultados Nos 54 membros inferiores submetidos ao tratamento, comparando-se o período pré-operatório e o 30º dia pós-operatório, houve diferença significativa (p < 0,003) na redução do diâmetro da VSP tratada (6,37 mm pré-operatório e 5,15 mm no 30º dia pós-operatório) (IC95% 4,58-5,72) e na melhora do escore de gravidade clínica venosa (VCSS) (média de 8,02 pré-operatório e 6,11 no 30º dia pós-operatório) (IC95% 5,01-7,21) (p < 0,02). Complicações pós-operatórias, como parestesia e flebite, estiveram presentes e foram diagnosticadas em cinco e três pacientes, respectivamente, sem significar alteração na qualidade de vida e nas atividades de rotina. Conclusões A técnica de termoablação com laser da VSP mostrou-se segura e eficaz na redução dos sintomas clínicos e na melhora da qualidade de vida.
Direitos para esta edição cedidos à Atena Editora pelos autores. Todo o conteúdo deste livro está licenciado sob uma Licença de Atribuição Creative Commons. Atribuição-Não-Comercial-NãoDerivativos 4.0 Internacional (CC BY-NC-ND 4.0). O conteúdo dos artigos e seus dados em sua forma, correção e confiabilidade são de responsabilidade exclusiva dos autores, inclusive não representam necessariamente a posição oficial da Atena Editora. Permitido o download da obra e o compartilhamento desde que sejam atribuídos créditos aos autores, mas sem a possibilidade de alterá-la de nenhuma forma ou utilizá-la para fins comerciais. A Atena Editora não se responsabiliza por eventuais mudanças ocorridas nos endereços convencionais ou eletrônicos citados nesta obra. Todos os manuscritos foram previamente submetidos à avaliação cega pelos pares, membros do Conselho Editorial desta Editora, tendo sido aprovados para a publicação.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.