The availability of a non-invasive express method for the in vivo measurement of both sound velocity and thickness of the human skull bone would be of great benefit to various transcranial ultrasonic imaging and treatment applications. This paper investigates two ultrasonic methods that measure both parameters and are based on the variable focus technique. All the experiments described in this paper were conducted on specially prepared custom skull bone phantoms, including flat and deformed samples, designed and developed in our laboratory. The first method uses a single immersion 2.25 MHz ultrasonic transducer consecutively focused on the front and back surfaces of the sample. The accuracy and precision of this method are demonstrated via single point measurements on flat samples with and without porosity. The measurement results from a specimen with the randomly curved back surface show the possibility of obtaining the inner profile of the skull bone. The second presented method is a practical modification of the variable focus technique for the linear phased array case. The method was tested on flat and curved skull bone phantoms with and without inner porosity showing higher measurement accuracy and simpler practical realization than its scanning counterpart.
In the various stages of developing diagnostic and therapeutic equipment, the use of phantoms can play a very important role in improving the process, help in implementation, testing and calibrations. Phantoms are especially useful in developing new applications and training new doctors in medical schools. However, devices that use different physical factors, such as MRI, Ultrasound, CT Scan, etc will require the phantom to be made of different physical properties. In this paper we introduce the properties of recently designed new materials for developing phantoms for ultrasonic human body investigation, which in today's market make up more than 30% in the world of phantoms. We developed a novel composite material which allows fabrication of various kinds of ultrasound bone phantoms to mimic most of the acoustical properties of human bones. In contrast to the ex vivo tissues, the proposed material can maintain the physical and acoustical properties unchanged for long periods of time; moreover, these properties can be custom designed and created to suit specific needs. As a result, we introduce three examples of ultrasound phantoms that we manufactured in our laboratory: cortical, trabecular and skull bone phantoms. The paper also presents the results of a comparison study between the acoustical and physical properties of actual human bones (reported in the referenced literatures) and the phantoms manufactured by us.
A new adaptive beamforming algorithm for imaging via small-aperture 1-D ultrasonic-phased arrays through composite layered structures is reported. Such structures cause acoustic phase aberration and wave refraction at undulating interfaces and can lead to significant distortion of an ultrasonic field pattern produced by conventional beamforming techniques. This distortion takes the form of defocusing the ultrasonic field transmitted through the barrier and causes loss of resolution and overall degradation of image quality. To compensate for the phase aberration and the refractional effects, we developed and examined an adaptive beamforming algorithm for small-aperture linear-phased arrays. After accurately assessing the barrier's local geometry and sound speed, the method calculates a new timing scheme to refocus the distorted beam at its original location. As a tentative application, implementation of this method for trans-skull imaging of certain types of head injuries through human skull is discussed. Simulation and laboratory results of applying the method on skull-mimicking phantoms are presented. Correction of up to 2.5 cm focal point displacement at up to 10 cm depth under our skull phantom is demonstrated. Quantitative assessment of the method in a variety of temporal focusing scenarios is also reported. Overall temporal deviation on the order of a few nanoseconds was observed between the simulated and experimental results. The single-point adaptive focusing results demonstrate strong potential of our approach for diagnostic imaging through intact human skull. The algorithms were implemented on an ultrasound advanced open-platform controlling 64 active elements on a 128-element phased array.
Duringultrasonic testing of resistance spot welds in real time the probe sends the sound waves through the thickness of the copper electrode cap into the materials being welded. Characteristics of the reflected waves from the weld interfaces allow a reliable decision to be made on the quality of the joint. Transmission of high frequency sound waves through the relatively thick copper welding cap cause the signal to be greatly attenuated due to grain scattering. For this reason, close monitoring of the copper cap properties prior to installation is essential for adequate performance. Finding copper alloys with a small average grain sizes is essential to minimize the attenuating effects. The conducted backscatter and attenuation experiments indicate correlation between the ultrasonically measured parameters and the optically found copper grain size. This correlation suggests that the attenuation or backscatter technique could be used alone in order to validate the proper copper alloy to be used in spot weld probes. Using non-destructive testing techniques for this purpose greatly reduces the time and cost involved compared to optical techniques.
We report a new progress in the development of a portable ultrasonic transcranial imaging system, which is expected to significantly improve the clinical utility of transcranial diagnostic ultrasound. When conventional ultrasonic phased array and Doppler techniques are applied through thick skull bones, the ultrasound field is attenuated, deflected, and defocused, leading to image distortion. To address these deficiencies, the ultrasonic transcranial imaging system implements two alternative ultrasonic methods. The first method improves detection of small foreign objects, such as bone fragments, pieces of shrapnel, or bullets, lodged in the brain tissue. Using adaptive beamforming, the method compensates for phase aberration induced by the skull and refocuses the distorted ultrasonic field at the desired location. The second method visualizes the blood flow through intact human skull using ultrasonic speckle reflections from the blood cells, platelets, or contrast agents. By analyzing these random temporal changes, it is possible to obtain 2D or 3D blood flow images, despite the adverse influence of the skull. Both methods were implemented on an advanced open platform phased array controller driving linear and matrix array probes. They were tested on realistic skull bone and head phantoms with foreign inclusions and blood vessel models.
Objectives Essential Tremor (ET) is one of the most common neurologic conditions, and conservative measures are frequently suboptimal. Recent data from a multi-institution, randomized controlled clinical trial demonstrated that Magnetic Resonance-guided Focused Ultrasound (MRgFUS) thalamotomy improves upper limb tremor in medically refractory ET. This study assesses the cost-effectiveness of this novel therapy in comparison to existing procedural options. Methods PubMed and Cochrane Library searches were performed for studies of MRgFUS, Deep Brain Stimulation (DBS), and Stereotactic Radiosurgery (SRS) for ET. Pre-and post-operative tremor-related disability scores were collected from 32 studies involving 83 MRgFUS, 615 DBS, and 260 SRS cases. Utility (defined as percent change in functional disability) was calculated, and Medicare reimbursements were collected as a proxy for societal cost -costs of MRgFUS for ET were derived from a combination of available costs of approved indications and SRS costs where appropriate. A decision and cost-effectiveness analysis was then constructed, implementing meta-analytic techniques. Results MRgFUS thalamotomy resulted in significantly higher utility scores compared with DBS and SRS based on estimates of Medicare reimbursement (p < 0.001). MRgFUS was also the most inexpensive procedure out of the three (p < 0.001). Conclusions Preliminary experience with MRgFUS for ET suggests that this novel therapeutic may be more effective than available alternatives and potentially less costly for society. It thus will likely "dominate" DBS and SRS as a more cost-effective option for medically refractory ET. Our findings support further investigation of MRgFUS for ET and broad adoption. Objectives The ventral intermediate nucleus (VIM) is not visible on conventional Magnetic Resonance Imaging (MRI).A novel method for tractography-based VIM identification has recently been described. We report the short-term clinical results of prospective VIM targeting with tractography in a cohort of patients undergoing Focused Ultrasound thalamotomy. Methods All patients underwent structural and diffusion weighted imaging (60 diffusion directions, 2 mm isovoxel) with 3 Tesla MRI scanner (Philips Ingenia CX). The images were processed using streamline tractography (Stealth Viz, Medtronic Inc.). The lateral and posterior borders of VIM were defined by tracking the pyramidal tract and medial lemniscus respectively. A VIM region of interest (ROI) was placed 3 mm away from these borders (Figs. 1, 2 and 3). The structural connectivity of this VIM ROI was confirmed to the motor cortex (M1) and cerebellum. The coordinates of tractography-based VIM in relation to posterior commissure were noted for surgical targeting. The parameters analyzed include a clinical tremor scale (pre-, intraoperative, and post operative), operative time, and number of sonications. Results Tractography-based VIM targeting was successful in 7 out of 8 patients. The coordinates of tractography-based VIM were significantly different from...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.