Ventricular tachycardia (VT), which can lead to sudden cardiac death, occurs frequently in patients with myocardial infarction. Catheter-based radiofrequency ablation of cardiac tissue has achieved only modest efficacy, owing to the inaccurate identification of ablation targets by current electrical mapping techniques, which can lead to extensive lesions and to a prolonged, poorly tolerated procedure. Here we show that personalized virtual-heart technology based on cardiac imaging and computational modelling can identify optimal infarct-related VT ablation targets in retrospective animal (5 swine) and human studies (21 patients) and in a prospective feasibility study (5 patients). We first assessed in retrospective studies (one of which included a proportion of clinical images with artifacts) the capability of the technology to determine the minimum-size ablation targets for eradicating all VTs. In the prospective study, VT sites predicted by the technology were targeted directly, without relying on prior electrical mapping. The approach could improve infarct-related VT ablation guidance, where accurate identification of patient-specific optimal targets could be achieved on a personalized virtual heart prior to the clinical procedure.
Atrial fibrillation (AF) -the most common arrhythmia -significantly increases the risk of stroke and heart failure. Although catheter ablation can restore normal heart rhythms, patients with persistent AF who develop atrial fibrosis often undergo multiple failed ablations and thus increased procedural risks. Here, we present personalized computational modelling for the reliable predetermination of ablation targets, which are then used to guide the ablation procedure in patients with persistent AF and atrial fibrosis. We first show that a computational model of the atria of patients identifies fibrotic tissue that if ablated will not sustain AF. We then integrated the target-ablation sites in a clinical-mapping system, and tested its feasibility in 10 patients with persistent AF. The computational prediction of ablation targets avoids lengthy electrical mapping Reprints and permissions information is available at www.nature.com/reprints.Users may view, print, copy, and download text and data-mine the content in such documents, for the purposes of academic research, subject always to the full Conditions of use:
In this paper we present a benchmarking framework for the validation of cardiac motion analysis algorithms. The reported methods are the response to an open challenge that was put to the medical imaging community through a MICCAI workshop. The database included magnetic resonance (MR) and 3D ultrasound (3DUS) datasets from a dynamic phantom and 15 healthy volunteers. Participants processed 3D tagged MR datasets (3DTAG), cine steady state free precession MR datasets (SSFP) and 3DUS datasets, amounting to 1158 image volumes. Ground-truth for motion tracking was based on 12 landmarks (4 walls at 3 ventricular levels). They were manually tracked by two observers in the 3DTAG data over the whole cardiac cycle, using an in-house application with 4D visualization capabilities. The median of the inter-observer variability was computed for the phantom dataset (0.77mm) and for the volunteer datasets (0.84mm). The ground-truth was registered to 3DUS coordinates using a point based similarity transform. Four institutions responded to the challenge by providing motion estimates for the data: Fraunhofer MEVIS (MEVIS), Bremen, Germany; Imperial College London -University College London (IUCL), UK; Universitat Pompeu Fabra (UPF), Barcelona, Spain; Inria-Asclepios project (INRIA), France. Details on the implementation and evaluation of the four methodologies are presented in this manuscript. The manually tracked landmarks were used to evaluate tracking accuracy of all methodologies. For 3DTAG, median values were computed over all time frames for the phantom dataset (MEVIS=1.20mm, IUCL=0.73mm, UPF=1.10mm, INRIA=1.09mm) and for the volunteer datasets (MEVIS=1.33mm, IUCL=1.52mm, UPF=1.09mm, INRIA=1.32mm). For 3DUS, median values were computed at end diastole and end systole for the phantom dataset (MEVIS=4.40mm, UPF=3.48mm, INRIA=4.78mm) and for the volunteer datasets (MEVIS=3.51mm, UPF=3.71mm, INRIA=4.07mm). For SSFP, median values were computed at end diastole and end systole for the phantom dataset (UPF=6.18mm, INRIA=3.93mm) and for the volunteer datasets (UPF=3.09mm, INRIA=4.78mm). Finally, strain curves were generated and qualitatively compared. Good agreement was found between the different modalities and methodologies, except for radial strain that showed a high variability in cases of lower image quality.
BACKGROUND Left atrial flutter (LAFL) occurs in patients after atrial fibrillation ablation. Identification of optimal ablation targets to terminate LAFL remains challenging. OBJECTIVE The purpose of this study was to use patient-specific models to simulate LAFL and predict optimal ablation targets using a novel approach based on flow network theory. METHODS Late gadolinium-enhanced cardiac magnetic resonance scans from 10 patients with LAFL were used to construct atrial models incorporating fibrosis by investigators blinded to procedural findings. Rapid pacing was applied in silico to induce LAFL. In each LAFL, we represented reentrant wave propagation as an electric flow network and identified the “minimum cut” (MC), which was the smallest amount of tissue that separated the flow into 2 discontinuous components. In silico ablation was applied at MCs, and targets were compared to those that terminated LAFL during catheter ablation. RESULTS Patient-specific atrial models were successfully generated from patient scans. LAFL was induced in 7 of 10 models. Ablation of MCs terminated LAFL in 4 models and produced new, slower LAFL morphologies in the other 3. For the latter cases, flow analysis was repeated to identify MCs of emergent LAFLs. Ablation of these MCs terminated emergent LAFLs. The MC-based ablation lesions in simulations were similar in length and location to ablation targets that terminated LAFL during catheter ablation for these 7 patients. CONCLUSION Personalized atrial simulations can predict ablation targets for LAFL. These simulations provide a powerful tool for planning ablation procedures and may reduce procedural times and complications.
Identification of optimal ablation sites in hearts with infarct-related ventricular tachycardia (VT) remains difficult to achieve with the current catheter-based mapping techniques. Limitations arise from the ambiguities in determining the reentrant pathways location(s). The goal of this study was to develop experimentally validated, individualized computer models of infarcted swine hearts, reconstructed from high-resolution ex-vivo MRI and to examine the accuracy of the reentrant circuit location prediction when models of the same hearts are instead reconstructed from low clinical-resolution MRI scans. To achieve this goal, we utilized retrospective data obtained from four pigs ~10 weeks post infarction that underwent VT induction via programmed stimulation and epicardial activation mapping via a multielectrode epicardial sock. After the experiment, high-resolution ex-vivo MRI with late gadolinium enhancement was acquired. The Hi-res images were downsampled into two lower resolutions (Med-res and Low-res) in order to replicate image quality obtainable in the clinic. The images were segmented and models were reconstructed from the three image stacks for each pig heart. VT induction similar to what was performed in the experiment was simulated. Results of the reconstructions showed that the geometry of the ventricles including the infarct could be accurately obtained from Med-res and Low-res images. Simulation results demonstrated that induced VTs in the Med-res and Low-res models were located close to those in Hi-res models. Importantly, all models, regardless of image resolution, accurately predicted the VT morphology and circuit location induced in the experiment. These results demonstrate that MRI-based computer models of hearts with ischemic cardiomyopathy could provide a unique opportunity to predict and analyze VT resulting for from specific infarct architecture, and thus may assist in clinical decisions to identify and ablate the reentrant circuit(s).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.