BackgroundAccess to ultrasound has increased significantly in resource-limited settings, including the developing world; however, there remains a lack of sonography education and ultrasound-trained physician support in developing countries. To further investigate this potential knowledge gap, our primary objective was to assess perceived barriers to ultrasound use in resource-limited settings by surveying care providers who practice in low- and middle-income settings.MethodsA 25-question online survey was made available to health care providers who work with an ultrasound machine in low- and middle-income countries (LMICs), including doctors, nurses, technicians, and clinical officers. This was a convenience sample obtained from list-serves of ultrasound and radiologic societies. The survey was analyzed, and descriptive results were obtained.ResultsOne hundred and thirty-eight respondents representing 44 LMICs including countries from the continents of Africa, South America, and Asia completed the survey, with a response rate of 9.6 %. Ninety-one percent of the respondents were doctors, and 9 % were nurses or other providers. Applications for ultrasound were diverse, including obstetrics (75 %), DVT evaluation (51 %), abscess evaluation (54 %), cardiac evaluation (64 %), inferior vena cava (IVC) assessment (49 %), Focused Assessment Sonography for Trauma (FAST) exam (64 %), biliary tree assessment (54 %), and other applications. The respondents identified the following barriers to use of ultrasound: lack of training (60 %), lack of equipment (45 %), ultrasound machine malfunction (37 %), and lack of ultrasound maintenance capability (47 %). Seventy-four percent of the respondents wished to have further training in ultrasound, and 82 % were open to receiving distance learning or telesonography training. Subjects used communication tools including Skype, Dropbox, emailed photos, and picture archiving and communication system (PACS) as ways to communicate and receive feedback on ultrasound images.ConclusionsHealth care providers in the developing world identify lack of training as a primary barrier to regular use of ultrasound in their practice. While equipment requirements including maintenance and cost of machines are also important factors, future research is warranted on best practices for training methods, including telesonography and distance learning to enhance ultrasound use in low-resource settings.
Background A subset of high-risk procedures present significant safety threats due to their (1) infrequent occurrence, (2) execution under time constraints and (3) immediate necessity for patient survival. A Just-in-Time (JIT) intervention could provide real-time bedside guidance to improve high-risk procedural performance and address procedural deficits associated with skill decay. Objective To evaluate the impact of a novel JIT intervention on transvenous pacemaker (TVP) placement during a simulated patient event. Methods This was a prospective, randomised controlled study to determine the effect of a JIT intervention on performance of TVP placement. Subjects included boardcertified emergency medicine physicians from two hospitals. The JIT intervention consisted of a portable, bedside computer-based procedural adjunct. The primary outcome was performance during a simulated patient encounter requiring TVP placement, as assessed by trained raters using a technical skills checklist. Secondary outcomes included global performance ratings, time to TVP placement, number of critical omissions and System Usability Scale scores (intervention only). Results Groups were similar at baseline across all outcomes. Compared with the control group, the intervention group demonstrated statistically significant improvement in the technical checklist score (11.45 vs 23.44, p<0.001, Cohen's d effect size 4.64), the global rating scale (2.27 vs 4.54, p<0.001, Cohen's d effect size 3.76), and a statistically significant reduction in critical omissions (2.23 vs 0.68, p<0.001, Cohen's d effect size −1.86). The difference in time to procedural completion was not statistically significant between conditions (11.15 min vs 12.80 min, p=0.12, Cohen's d effect size 0.65). System Usability Scale scores demonstrated excellent usability. Conclusion A JIT intervention improved procedure perfromance, suggesting a role for JIT interventions in rarely performed procedures.
IntroductionIn low-resource settings it is not always possible to acquire the information required to diagnose acute respiratory distress syndrome (ARDS). Ultrasound and pulse oximetry, however, may be available in these settings. This study was designed to test whether pulmonary ultrasound and pulse oximetry could be used in place of traditional radiographic and oxygenation evaluation for ARDS.MethodsThis study was a prospective, single-center study in the ICU of Harborview Medical Center, a referral hospital in Seattle, Washington, USA. Bedside pulmonary ultrasound was performed on ICU patients receiving invasive mechanical ventilation. Pulse oximetric oxygen saturation (SpO2), partial pressure of oxygen (PaO2), fraction of inspired oxygen (FiO2), provider diagnoses, and chest radiograph closest to time of ultrasound were recorded or interpreted.ResultsOne hundred and twenty three ultrasound assessments were performed on 77 consecutively enrolled patients with respiratory failure. Oxygenation and radiographic criteria for ARDS were met in 35 assessments. Where SpO2 ≤ 97 %, the Spearman rank correlation coefficient between SpO2/FiO2 and PaO2/FiO2 was 0.83, p < 0.0001. The sensitivity and specificity of the previously reported threshold of SpO2/FiO2 ≤ 315 for PaO2/FiO2 ≤ 300 was 83 % (95 % confidence interval (CI) 68–93), and 50 % (95 % CI 1–99), respectively. Sensitivity and specificity of SpO2/FiO2 ≤ 235 for PaO2/FiO2 ≤ 200 was 70 % (95 % CI 47–87), and 90 % (95 % CI 68–99), respectively. For pulmonary ultrasound assessments interpreted by the study physician, the sensitivity and specificity of ultrasound interstitial syndrome bilaterally and involving at least three lung fields were 80 % (95 % CI 63–92) and 62 % (95 % CI 49–74) for radiographic criteria for ARDS. Combining SpO2/FiO2 with ultrasound to determine oxygenation and radiographic criteria for ARDS, the sensitivity was 83 % (95 % CI 52–98) and specificity was 62 % (95 % CI 38–82). For moderate–severe ARDS criteria (PaO2/FiO2 ≤ 200), sensitivity was 64 % (95 % CI 31–89) and specificity was 86 % (95 % CI 65–97). Excluding repeat assessments and independent interpretation of ultrasound images did not significantly alter the sensitivity measures.ConclusionsPulse oximetry and pulmonary ultrasound may be useful tools to screen for, or rule out, impaired oxygenation or lung abnormalities consistent with ARDS in under-resourced settings where arterial blood gas testing and chest radiography are not readily available.Electronic supplementary materialThe online version of this article (doi:10.1186/s13054-015-0995-5) contains supplementary material, which is available to authorized users.
Objective Point-of-care ultrasound (POCUS) is a vital tool for diagnosis and management of critically ill patients, particularly in resource-limited settings where access to diagnostic imaging may be constrained. We aimed to develop a novel POCUS training curriculum for surgical practice in the United States and in resource-limited settings in low- and middle-income countries and to determine its effect on surgical resident self-assessments of efficacy and confidence. Design We conducted an observational cohort study evaluating a POCUS training course that comprised 7 sessions of 2 hours each with didactics and proctored skills stations covering ultrasound applications for trauma (Focused Assessement with Sonography for Trauma (FAST) examination), obstetrics, vascular, soft tissue, regional anesthesia, focused echocardiography, and ultrasound guidance for procedures. Surveys on attitudes, prior experience, and confidence in point-of-care ultrasound applications were conducted before and after the course. Setting General Surgery Training Program in Seattle, Washington. Participants A total of 16 residents participated in the course; 15 and 10 residents completed the precourse and postcourse surveys, respectively. Results The mean composite confidence score from pretest compared with posttest improved from 23.3 (±10.2) to 37.8 (±6.7). Median confidence scores (1-6 scale) improved from 1.5 to 5.0 in performance of FAST (p < 0.001). Residents reported greater confidence in their ability to identify pericardial (2 to 4, p = 0.009) and peritoneal fluid (2 to 4.5, p < 0.001), to use ultrasound to guide procedures (3.5 to 4.0, p = 0.008), and to estimate ejection fraction (1 to 4, p = 0.004). Both before and after training, surgical residents overwhelmingly agreed with statements that ultrasound would improve their US-based practice, make them a better surgical resident, and improve their practice in resource-limited settings. Conclusions After a POCUS course designed specifically for surgeons, surgical residents had improved self-efficacy and confidence levels across a broad range of skills.
BACKGROUND Bidimensional tumor measurements are used routinely as surrogates for tumor volume. The purpose this study was to determine whether there is any added benefit in bidimensional or tridimensional measurements over a unidimensional measurement. METHODS Sixty‐nine colorectal hepatic metastases on 19 computed tomography scans (1–8 lesions per scan) from 9 patients were analyzed. Five patients contributed 2–4 scans each (mean, 3 scans). The standard volume of these lesions was determined by the “summation of areas” technique. The maximum axial dimension, the product of the greatest axial dimensions, and several volume estimates (based on the volumes of a sphere, an ellipsoid, and a cube) each were correlated with the standard volume. RESULTS The maximum axial dimension and the product of the greatest axial dimensions correlated equally with tumor volume (correlation coefficient = 0.93). Surrogate measures based on the equations for a sphere and an ellipsoid underestimated tumor volume, whereas the equation for a cube overestimated volume. CONCLUSIONS When reporting tumor size, there is no significant added benefit in reporting bidimensional or tridimensional measurements over the maximum axial dimension. Cancer 2001;91:555–60. © 2001 American Cancer Society.
When reporting tumor size, there is no significant added benefit in reporting bidimensional or tridimensional measurements over the maximum axial dimension.
Agranulocytosis is a rare yet life-threatening complication of methimazole therapy for hyperthyroidism. We present the case of a 37-year-old female recently started on methimazole for hyperthyroidism who presented to our facility for evaluation of suspected thyroid storm. In addition to having abnormal thyroid indices, she was noted to have an odontogenic abscess, and was septic with profound neutropenia. Her symptoms resolved quickly following incision and drainage of her abscess and treatment with broad-spectrum antibiotics. Her neutrophil count improved significantly following cessation of methimazole and administration of granulocyte colony-stimulating factor. Diagnosis was initially confounded by the similarity between symptoms of early sepsis and those of thyroid storm. This case report discusses the factors leading to diagnostic delay and highlights the dangerous manifestations of neutropenia in patients on methimazole therapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.