SUMMARYWe propose an efficient numerical algorithm for computing deformations of 'very' soft tissues (such as the brain, liver, kidney etc.), with applications to real-time surgical simulation. The algorithm is based on the finite element method using the total Lagrangian formulation, where stresses and strains are measured with respect to the original configuration. This choice allows for pre-computing of most spatial derivatives before the commencement of the time-stepping procedure.We used explicit time integration that eliminated the need for iterative equation solving during the time-stepping procedure. The algorithm is capable of handling both geometric and material non-linearities. The total Lagrangian explicit dynamics (TLED) algorithm using eight-noded hexahedral under-integrated elements requires approximately 35% fewer floating-point operations per element, per time step than the updated Lagrangian explicit algorithm using the same elements.Stability analysis of the algorithm suggests that due to much lower stiffness of very soft tissues than that of typical engineering materials, integration time steps a few orders of magnitude larger than what is typically used in engineering simulations are possible.Numerical examples confirm the accuracy and efficiency of the proposed TLED algorithm.
SUMMARYA method is presented for computing deformation of very soft tissue. The method is motivated by the need for simple, automatic model creation for real-time simulation. The method is meshless in the sense that deformation is calculated at nodes that are not part of an element mesh. Node placement is almost arbitrary. Fully geometrically nonlinear Total Lagrangian formulation is used. Geometric integration is performed over a regular background grid that does not conform to the simulation geometry. Explicit time integration is used via the central difference method. As an example the simple but fully nonlinear Neo-Hookean material model is employed. The results are compared with a finite element simulation to verify the usefulness of the method.
Application of biomechanical modeling techniques in the area of medical image analysis and surgical simulation implies two conflicting requirements: accurate results and high solution speeds. Accurate results can be obtained only by using appropriate models and solution algorithms. In our previous papers we have presented algorithms and solution methods for performing accurate nonlinear finite element analysis of brain shift (which includes mixed mesh, different non-linear material models, finite deformations and brain-skull contacts) in less than a minute on a personal computer for models having up to 50.000 degrees of freedom. In this paper we present an implementation of our algorithms on a Graphics Processing Unit (GPU) using the new NVIDIA Compute Unified Device Architecture (CUDA) which leads to more than 20 times increase in the computation speed. This makes possible the use of meshes with more elements, which better represent the geometry, are easier to generate, and provide more accurate results.
Long computation times of non-linear (i.e. accounting for geometric and material non-linearity) biomechanical models have been regarded as one of the key factors preventing application of such models in predicting organ deformation for image-guided surgery. This contribution presents real-time patient-specific computation of the deformation field within the brain for six cases of brain shift induced by craniotomy (i.e. surgical opening of the skull) using specialised non-linear finite element procedures implemented on a graphics processing unit (GPU). In contrast to commercial finite element codes that rely on an updated Lagrangian formulation and implicit integration in time domain for steady state solutions, our procedures utilise the total Lagrangian formulation with explicit time stepping and dynamic relaxation. We used patient-specific finite element meshes consisting of hexahedral and non-locking tetrahedral elements, together with realistic material properties for the brain tissue and appropriate contact conditions at the boundaries. The loading was defined by prescribing deformations on the brain surface under the craniotomy. Application of the computed deformation fields to register (i.e. align) the preoperative and intraoperative images indicated that the models very accurately predict the intraoperative deformations within the brain. For each case, computing the brain deformation field took less than 4 s using a NVIDIA Tesla C870 GPU, which is two orders of magnitude reduction in computation time in comparison to our previous study in which the brain deformation was predicted using a commercial finite element solver executed on a personal computer.
Imaging modalities that can be used intra-operatively do not provide sufficient details to confidently locate the abnormalities and critical healthy areas that have been identified from highresolution pre-operative scans. However, as we have shown in our previous work, high quality pre-operative images can be warped to the intra-operative position of the brain. This can be achieved by computing deformations within the brain using a biomechanical model. In this paper, using a previously developed patient-specific model of brain undergoing craniotomy-induced shift, we conduct a parametric analysis to investigate in detail the influences of constitutive models of the brain tissue. We conclude that the choice of the brain tissue constitutive model, when used with an appropriate finite deformation solution, does not affect the accuracy of computed displacements, and therefore a simple linear elastic model for the brain tissue is sufficient.
Many researchers have proposed the use of biomechanical models for high accuracy soft organ non-rigid image registration, but one main problem in using comprehensive models is the long computation time required to obtain the solution. In this paper we propose to use the Total Lagrangian formulation of the Finite Element method together with Dynamic Relaxation for computing intra-operative organ deformations. We study the best ways of estimating the parameters involved and we propose a termination criteria that can be used in order to obtain fast results with prescribed accuracy. The simulation results prove the accuracy and computational efficiency of the method, even in cases involving large deformations, nonlinear materials and contacts.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.