Background and objectivesQuadratus lumborum (QL) block is a new regional analgesic technique for upper and lower abdominal surgeries as part of a multimodal analgesic regime. It has also been reported to relieve pain after total hip arthroplasty (THA). In this prospective, randomized, double-blind study, we compared QL block with control (no block) in patients undergoing primary THA.MethodsEighty patients undergoing primary THA surgery under spinal anesthesia were randomized into two groups, one with and one without QL block. The patients in both groups were randomized after sedation, positioning and ultrasound scanning. Both the patient and the researcher collecting data were blinded to the patient’s group assignment. Opioid consumption and visual analog scores (VAS) pain scores were measured at 12, 24, and 48 hours after surgery. Also, the ambulation distance, patient satisfaction, and length of stay were recorded.ResultsThe study analysis included 36 patients in the QL group and 35 patients in the control group. Both VAS pain score at 24 hours (difference −1.76, 95% CI −2.87 to −0.64) and cumulative opioid consumption were significantly lower in the QL group at 12, 12–24, 24, 24–48, and 48 hours after surgery as compared with the control group (difference at 48 hours −36.13, 95% CI −62.89 to −9.37) (p<0.05). However, there was no difference in pain score at 12 and 48 hours, nor in the ambulation distance and duration of hospital stay between the two groups. The patient satisfaction score was significantly higher in the QL group.ConclusionsOur preliminary data show that the QL block provided effective analgesia and decreased opioid requirements up to 48 hours after primary THA.Trial registration numberNCT03408483
BACKGROUND:
Preeclampsia (PE) manifesting as hypertension and organ injury is mediated by vascular dysfunction. In biological fluids, extracellular vesicles (EVs) containing microRNA (miRNA), protein, and other cargo released from the placenta may serve as carriers to propagate injury, altering the functional phenotype of endothelial cells. PE has been consistently correlated with increased levels of placenta-derived EVs (pEVs) in maternal circulation. However, whether pEVs impaired endothelial cell function remains to be determined. In this study, we hypothesize that pEVs from pregnant women with severe PE (sPE) impair endothelial function through altered cell signaling.
METHODS:
We obtained plasma samples from women with sPE (n = 14) and normotensive pregnant women (n = 15) for the isolation of EVs. The total number of EV and pEV contribution was determined by quantifying immunoreactive EV-cluster of designation 63 (CD63) and placental alkaline phosphatase (PLAP) as placenta-specific markers, respectively. Vascular endothelial functional assays were determined by cell migration, electric cell-substrate impedance sensing in human aortic endothelial cells (HAECs), and wire myography in isolated blood vessels, preincubated with EVs from normotensive and sPE women.
RESULTS:
Plasma EV and pEV levels were increased in sPE when compared to normotensive without a significant size distribution difference in sPE (108.8 ± 30.2 nm) and normotensive-EVs (101.3 ± 20.3 nm). Impaired endothelial repair and proliferation, reduced endothelial barrier function, reduced endothelial-dependent vasorelaxation, and decreased nitrite level indicate that sPE-EVs induced vascular endothelial dysfunction. Moreover, sPE-EVs significantly downregulated endothelial nitric oxide synthase (eNOS and p-eNOS) when compared to normotensive-EV.
CONCLUSIONS:
EVs from sPE women impair endothelial-dependent vascular functions in vitro.
Objective
Acute kidney injury (AKI) is a common complication of complex aortic surgery with high mortality, morbidity and health care expense. The current definition of AKI does not allow for structural characterization of the kidneys and utilizes functional indices with substantial limitations leading to delayed diagnosis and ineffective interventions. The aim of this study is to develop a method of early detection of structural renal abnormalities that can precede and predict the occurrence of AKI in this population. We propose a novel combined index of ultrasonography (shear wave elastography), biomarkers of renal stress (urinary insulin growth factor binding protein-7, IGFBP-7 and inhibitor of tissue metalloproteinase-2, TIMP-2) and renal injury markers (urinary neutrophil gelatinase-associated lipocalin -NGAL)- the bio-sonographic index (BSI).
Methods
A prospective observational study at a tertiary referral center will be performed enrolling 80 patients undergoing elective open and endovascular repair of the visceral aorta. The BSI will be evaluated at baseline, and at 6 and 24 hours after the procedure. The primary outcome is the occurrence of AKI according to the Kidney Disease Improving Global Outcomes (KDIGO) criteria. Each patient will be his/her own control. A reference group of 15 healthy volunteers who are not undergoing interventions will be enrolled to test the feasibility of and to refine the novel SWE protocol. The BSI will be tested for its predictability of the occurrence of AKI. Comparisons will be made between individual and combined components of the BSI and traditional markers used in the KDIGO definition; serum creatinine and urine output in terms of baseline status of the kidney. Correlations will be made between the BSI and conventional indices of AKI and exploratory analyses will be conducted to identify individual disease patterns using the BSI.
Discussion
We hypothesize that the BSI will be a sensitive index of early structural abnormalities that precede and predict the occurrence of AKI as defined by KDIGO in complex vascular surgery.
Trial registration
ClinicalTrials.gov NCT04144894. Registered 1/6/2020.
Background and objective Pre-eclampsia (PEC) is associated with the release of anti-angiogenic factors that are incriminated in raising systemic and pulmonary vascular resistance (PVR). Compared to the left heart and systemic circulation, much less attention has been paid to the right heart and pulmonary circulation in patients with PEC. We used transthoracic echocardiography (TTE) to estimate pulmonary artery (PA) pressure and right ventricular (RV) function in women with PEC. Materials and methods We conducted a case-control study at a tertiary care academic center. Ten early PEC (<34-week gestation) and nine late PEC (≥34-week gestation) patients with 11 early and 10 late gestational age-matched controls were enrolled. Two-dimensional TTE was performed on all patients. The estimated mean PA pressure (eMPAP) was calculated based on PA acceleration time (PAAT). PVR was estimated from eMPAP and RV cardiac output (RV CO). RV myocardial performance index (RV MPI), tricuspid annular plane systolic excursion (TAPSE), tissue tricuspid annular displacement (TTAD), and lateral tricuspid annular tissue peak systolic velocity (S') were measured.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.