Significant changes in length, curvature, and twist occur in the PA and significant but more modest changes in length and twist occur in the SFA during movement from the SL to the CL position. This data has important implications for endovascular therapies that are used to treat disease in the FP artery.
Abstract-As the appreciation of structural heart disease in children and adults has increased and as catheter-based closure procedures are now being performed in clinical practice, cardiovascular physicians have multiple compelling new reasons to better understand cardiac anatomic and spatial relationships. Current 2-dimensional imaging techniques remain limited both in their ability to represent the complex 3-dimensional relationships present in structural heart disease and in their capacity to adequately facilitate often complex corrective procedures. This review discusses the cardiovascular applications of rapid prototyping, a new technology that may not only play a significant role in the planning of catheter-based interventions but also may serve as a valuable educational tool to enhance the medical community's understanding of the many forms of structural heart disease. Key Words: computed tomography Ⅲ heart defects, congenital Ⅲ heart septal defects Ⅲ percutaneous closure Ⅲ rapid prototyping C ardiovascular physicians and engineers have multiple compelling new reasons to better understand cardiac anatomic spatial relationships. First, congenital heart disease in children and adults has increased the appreciation of intracardiac shunt lesions and other anatomy-based lesions. In the last several years, there has been a dramatic increase in the number of both approved and investigative catheter-based therapies for congenital as well as acquired structural heart disease that involve both modification of structures and implantation of novel devices. Second, innovative cardiac valve interventions require an advanced understanding of spatial relationships and an ability to effectively navigate delivery systems within cardiac chambers. Finally, therapeutic intracardiac procedures in electrophysiology require an in-depth understanding of 3-dimensional (3D) relationships of cardiac structures to effectively perform both simple and complex ablation procedures.Fortunately, each of these new therapies has been accompanied by advances in medical imaging modalities that permit a more accurate, noninvasive assessment of cardiac defects. Current 2-dimensional (2D) imaging techniques, however, fall short both in representing the complex 3D relationships present in structural heart disease and adequately facilitating often complex corrective procedures. The physician must instead integrate the 2D images in his/her mind and conceptually extract the relevant 3D relationships. Although computer graphics allow for 3D representations of cardiac structures using processed 2D images from modalities such as ultrasound and multidetector computed tomography (CT), these representations remain limited by their overall lack of realism, dependence on computer workstations for visualization, and inability to be tangibly manipulated. The recent development of rapid prototyping, a method by which 2D images are processed into 3D physical models, has provided a new way for physicians and engineers to more clearly understand complex spatial re...
The goal of this study was to determine the severity of vessel foreshortening in standard angiographic views used during percutaneous coronary intervention (PCI). Coronary angiography is limited by its two-dimensional (2D) representation of three-dimensional (3D) structures. Vessel foreshortening in angiographic images may cause errors in the assessment of lesions or the selection and placement of stents. To date, no technique has existed to quantify these 2D limitations or the performance of physicians in selecting angiographic views. Stent deployment was performed in 156 vessel segments in 149 patients. Using 3D reconstruction models of each patient's coronary tree, vessel foreshortening was measured in the actual working view used for stent deployment. A computer-generated optimal view was then identified for each vessel segment and compared to the working view. Vessel foreshortening ranged from 0 to 50% in the 156 working views used for stent deployment and varied by coronary artery and by vessel segment within each artery. In general, views of the mid circumflex artery were the most foreshortened and views of the right coronary artery were the least foreshortened. Expert-recommended views frequently resulted in more foreshortening than computer-generated optimal views, which had only 0.5% +/- 1.2% foreshortening with < 2% overlap for the same 156 segments. Optimal views differed from the operator-selected working views by > or = 10 degrees in over 90% of vessels and frequently occurred in entirely different imaging quadrants. Vessel foreshortening occurs frequently in standard angiographic projections during stent deployment. If unrecognized by the operator, vessel foreshortening may result in suboptimal clinical results. Modifications to expert-recommended views using 3D reconstruction may improve visualization and the accuracy of stent deployment. These results highlight the limitations of 2D angiography and support the development of real-time 3D techniques to improve visualization during PCI.
Stent implantation results in important three-dimensional (3D) changes in arterial geometry which may be associated with adverse events. Previous attempts to quantify these 3D changes have been limited by two-dimensional techniques. Using a 3D reconstruction technique, vessel curvatures at end-diastole (ED) and end-systole (ES) were measured before and after stent placement of 100 stents (3 stent cell designs, 6 stent types). After stenting, the mean curvature at ED and ES decreased by 22 and 21%, respectively, and represents a straightening effect on the treated vessel. This effect was proportional to the amount of baseline curvature as high vessel curvature predicted more profound vessel straightening. When analyzed by stent cell design, closed-cell stents resulted in more vessel straightening than other designs (open cell or modified slotted tubes). Stent implantation resulted in the transmission of shape changes to stent ends and generated hinge points or buckling. Stent implantation creates 3D changes in arterial geometry which can be quantified using a 3D reconstruction technique.
DARCA represents a new angiographic technique which is equivalent in terms of image quality and is associated with less contrast use, radiation exposure, and procedural time than SA.
Being able to accurately choose an optimal view for stent positioning, non foreshortened length and to avoid side branches is imperative during therapeutic procedures. Traditional imaging limitations may include the selection of an incorrectly sized stent, inaccurate placement, and/or the need for additional stents. With the use of newer acquisition techniques and three-dimensional (3-D) modeling/reconstructions this can be minimized. We present a case in which with the assistance of 3-D and its computer derived optimal view, and optimal length, a significant amount of vessel foreshortening was eliminated therefore improving the procedural outcome.
Current expert-recommended views for coronary angiography are based on heuristic experience and have not been scientifically studied. We sought to identify optimal viewing regions for first and second order vessel segments of the coronary arteries that provide optimal diagnostic value in terms of minimizing vessel foreshortening and overlap. Using orthogonal 2D images of the coronary tree, 3D models were created from which patient-specific optimal view maps (OVM) allowing quantitative assessment of vessel foreshortening and overlap were generated. Using a novel methodology that averages 3D-based optimal projection geometries, a universal OVM was created for each individual coronary vessel segment that minimized both vessel foreshortening and overlap. A universal OVM model for each coronary segment was generated based on data from 137 patients undergoing coronary angiography. We identified viewing regions for each vessel segment achieving a mean vessel foreshortening value of 5.8 +/- 3.9% for the left coronary artery (LCA) and 5.6 +/- 3.6% for the right coronary artery (RCA). The overall mean overlap values achieved were 8.7 +/- 7.9% for the LCA and 4.6 +/- 3.2% for the RCA. This scientifically-based OVM evaluation of coronary vessel segments provides the means to facilitate acquisitions during coronary angiography and interventions that minimize imaging inaccuracies related to foreshortening and overlap, improving the accuracy, efficiency, and safety of diagnostic and interventional coronary procedures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.