Summary
Background
Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes.
Methods
For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a centralised computer system to receive a single large-diameter screw with a side-plate (sliding hip screw) or the present standard of care, multiple small-diameter cancellous screws. Surgeons and patients were not blinded but the data analyst, while doing the analyses, remained blinded to treatment groups. The primary outcome was hip reoperation within 24 months after initial surgery to promote fracture healing, relieve pain, treat infection, or improve function. Analyses followed the intention-to-treat principle. This study was registered with ClinicalTrials.gov, number NCT00761813.
Findings
Between March 3, 2008, and March 31, 2014, we randomly assigned 1108 patients to receive a sliding hip screw (n=557) or cancellous screws (n=551). Reoperations within 24 months did not differ by type of surgical fixation in those included in the primary analysis: 107 (20%) of 542 patients in the sliding hip screw group versus 117 (22%) of 537 patients in the cancellous screws group (hazard ratio [HR] 0.83, 95% CI 0.63–1.09; p=0.18). Avascular necrosis was more common in the sliding hip screw group than in the cancellous screws group (50 patients [9%] vs 28 patients [5%]; HR 1.91, 1.06–3.44; p=0.0319). However, no significant difference was found between the number of medically related adverse events between groups (p=0.82; appendix); these events included pulmonary embolism (two patients [<1%] vs four [1%] patients; p=0.41) and sepsis (seven [1%] vs six [1%]; p=0.79).
Interpretation
In terms of reoperation rates the sliding hip screw shows no advantage, but some groups of patients (smokers and those with displaced or base of neck fractures) might do better with a sliding hip screw than with cancellous screws.
Funding
National Institutes of Health, Canadian Institutes of Health Research, Stichting NutsOhra, Netherlands Organisation for Health Research and Development, Physicians’ Services Incorporated.
Joint replacement surgery is an available option for end-stage haemophilic arthropathy. However, reports with long-term follow-up are limited. Moreover, patient satisfaction in this setting has never been measured. We share our institution's experience with joint arthroplasty in haemophilic arthropathy and report on clinical outcomes and patient satisfaction. Between 1985 and 2007, 65 consecutive joints in 45 patients (mean age: 48.6; range: 22-83) underwent joint replacement surgery. Of these, 40 total knee replacements in 31 patients, 18 total hip replacements in 16 patients and 6 total elbow replacements in 3 patients were included. Average follow-up was 10.7 years (2.4-24.3). Charts were reviewed retrospectively and patients were asked to return for clinical assessment and completion of questionnaires. According to the Knee Society clinical score, postoperative results were good to excellent in 83% of knees. According to the Harris Hip Score, results were good to excellent in 31% of hips. According to the Mayo Elbow Performance Score, results were good to excellent in 83% of elbows. Complication rates are higher than in the non-haemophilic population, while prosthesis survival rates are lower. Patient satisfaction with pain relief is higher than satisfaction with functional improvement. For 88% of joints, patients are willing to have the same operation again. This study confirms previous knowledge on the role of total joint arthroplasty in haemophilic arthropathy. Despite high complication rates and modest functional outcomes, the operations are valuable for achieving pain relief. In general, patients find that risks are outweighed by the benefits.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.