This paper presents detailed measurements of the film-cooling effectiveness for three single, scaled-up film-cooling hole geometries. The hole geometries investigated include a cylindrical hole and two holes with a diffuser shaped exit portion (i.e. a fanshaped and a laidback fanshaped hole). The flow conditions considered are the crossflow Mach number at the hole entrance side (up to 0.6), the crossflow Mach number at the hole exit side (up to 1.2), and the blowing ratio (up to 2). The coolant-to-mainflow temperature ratio is kept constant at 0.54. The measurements are performed by means of an infrared camera system which provides a two-dimensional distribution of the film-cooling effectiveness in the nearfield of the cooling hole down to x/D = 10. As compared to the cylindrical hole, both expanded holes show significantly improved thermal protection of the surface downstream of the ejection location, particularly at high blowing ratios. The laidback fanshaped hole provides a better lateral spreading of the ejected coolant than the fanshaped hole which leads to higher laterally averaged film-cooling effectiveness. Coolant passage crossflow Mach number and orientation strongly affect the flowfield of the jet being ejected from the hole and, therefore, have an important impact on film-cooling performance.
The present study deals with the unsteady flow simulation of trailing edge film cooling on the pressure side cut back of gas turbine airfoils. Before being ejected tangentially on the inclined cut-back surface, the coolant air passes a partly converging passage that is equipped with turbulators such as pin fins and ribs. The film mixing process on the cut back is complicated. In the near slot region, due to the turbulators and the blunt pressure side lip, turbulence is expected to be anisotropic. Furthermore, unsteady flow phenomena like vortex shedding from the pressure side lip might influence the mixing process (i.e., the film cooling effectiveness on the cut-back surface). In the current study, three different internal cooling designs are numerically investigated starting from the steady RaNS solution, and ending with unsteady detached eddy simulations (DES). Blowing ratios M = 0.5; 0.8; 1.1 are considered. To obtain both, film cooling effectiveness as well as heat transfer coefficients on the cut-back surface, the simulations are performed using adiabatic and diabatic wall boundary conditions. The DES simulations give a detailed insight into the unsteady film mixing process on the trailing edge cut back, which is indeed influenced by vortex shedding from the pressure side lip. Furthermore, the time averaged DES results show very good agreement with the experimental data in terms of film cooling effectiveness and heat transfer coefficients. Transactions of the ASME Downloaded From: http://turbomachinery.asmedigitalcollection.asme.org/ on 09/18/2013 Terms of Use: http://asme.org/terms Journal of Turbomachinery APRIL 2006, Vol. 128 / 299 Downloaded From: http://turbomachinery.asmedigitalcollection.asme.org/ on 09/18/2013 Terms of Use: http://asme.org/terms
The present study deals with trailing edge film cooling on the pressure side cutback of gas turbine airfoils. Before being ejected tangentially onto the inclined cut-back surface the coolant air passes a partly converging passage that is equipped with turbulators such as pin fins and ribs. The experiments are conducted in a generic setup and cover a broad variety of internal cooling designs. A subsonic atmospheric open-loop wind tunnel is utilized for the tests. The test conditions are characterized by a constant Reynolds number of Re hg = 250 000, a turbulence intensity of Tu hg =7%, and a hot gas temperature of T hg = 500 K. Due to the ambient temperature of the coolant, engine realistic density ratios between coolant and hot gas can be realized. Blowing ratios cover a range of 0.20 Ͻ M Ͻ 1.25. The experimental data to be presented include discharge coefficients, adiabatic film cooling effectiveness, and heat transfer coefficients in the near slot region ͑x / H Ͻ 15͒. The results clearly demonstrate the strong influence of the internal cooling design and the relatively thick pressure side lip ͑t / H =1͒ on film cooling performance downstream of the ejection slot. Transactions of the ASME Downloaded From: http://turbomachinery.asmedigitalcollection.asme.org/ on 09/18/2013 Terms of Use: http://asme.org/terms Journal of Turbomachinery JANUARY 2006, Vol. 128 / 197 Downloaded From: http://turbomachinery.asmedigitalcollection.asme.org/ on 09/18/2013 Terms of Use: http://asme.org/terms Journal of Turbomachinery JANUARY 2006, Vol. 128 / 199 Downloaded From: http://turbomachinery.asmedigitalcollection.asme.org/ on 09/18/2013 Terms of Use: http://asme.org/terms
A comprehensive set of generic experiments has been conducted to investigate the effect of elevated free-stream turbulence on film cooling performance of shaped holes. A row of three cylindrical holes as a reference case, and two rows of holes with expanded exits, a fanshaped (expanded in lateral direction), and a laidback fanshaped hole (expanded in lateral and streamwise direction) have been employed. With an external (hot gas) Mach number of Mam=0.3 operating conditions are varied in terms of free-stream turbulence intensity (up to 11%), integral length scale at constant turbulence intensity (up to 3.5 hole inlet diameters), and blowing ratio. The temperature ratio is fixed at 0.59 leading to an enginelike density ratio of 1.7. The results indicate that shaped and cylindrical holes exhibit very different reactions to elevated free-stream turbulence levels. For cylindrical holes film cooling effectiveness is reduced with increased turbulence level at low blowing ratios whereas a small gain in effectiveness can be observed at high blowing ratios. For shaped holes, increased turbulence intensity is detrimental even for the largest blowing ratio M=2.5. In comparison to the impact of turbulence intensity the effect of varying the integral length scale is found to be of minor importance. Finally, the effect of elevated free-stream turbulence in terms of heat transfer coefficients was found to be much more pronounced for the shaped holes.
This paper presents detailed measurements of the film-cooling effectiveness for three single, scaled-up film-cooling hole geometries. The hole geometries investigated include a cylindrical hole and two holes with a diffuser-shaped exit portion (i.e., a fan-shaped and a laid-back fan-shaped hole). The flow conditions considered are the crossflow Mach number at the hole entrance side (up to 0.6), the crossflow Mach number at the hole exit side (up to 1.2), and the blowing ratio (up to 2). The coolant-to-mainflow temperature ratio is kept constant at 0.54. The measurements are performed by means of an infrared camera system, which provides a two-dimensional distribution of the film-cooling effectiveness in the near field of the cooling hole down to x/D = 10. As compared to the cylindrical hole, both expanded holes show significantly improved thermal protection of the surface downstream of the ejection location, particularly at high blowing ratios. The laidback fan-shaped hole provides a better lateral spreading of the ejected coolant than the fan-shaped hole, which leads to higher laterally averaged film-cooling effectiveness. Coolant passage cross-flow Mach number and orientation strongly affect the flowfield of the jet being ejected from the hole and, therefore, have an important impact on film-cooling performance.
One viable option to improve cooling methods used for gas turbine blades is to optimize the geometry of the film-cooling hole. To optimize that geometry, effects of the hole geometry on the complex jet-in-crossflow interaction need to be understood. This paper presents a comparison of detailed flowfield measurements for three different single, scaled-up, hole geometries all at a blowing ratio and density ratio of unity. The hole geometries include a round hole, a hole with a laterally expanded exit, and a hole with a forward-laterally expanded exit. In addition to the flowfield measurements for expanded cooling hole geometries being unique to the literature, the testing facility used for these measurements was also unique in that both the external mainstream Mach number (Ma∞ = 0.25) and internal coolant supply Mach number (Mac = 0.3) were nearly matched. Results show that by expanding the exit of the cooling holes, the penetration of the cooling jet as well as the intense shear regions are significantly reduced relative to a round hole. Although the peak turbulence levels for all three hole geometries was nominally the same, the source of that turbulence was different. The peak turbulence level for both expanded holes was located at the exit of the cooling hole resulting from the expansion angle being too large. The peak turbulence level for the round hole was located downstream of the hole exit where the velocity gradients were very large.
A comprehensive set of generic experiments has been conducted to investigate the effect of elevated free-stream turbulence on film cooling performance of shaped holes. A row of three cylindrical holes as a reference case, and two rows of holes with expanded exits, a fanshaped (expanded in lateral direction), and a laidback fanshaped hole (expanded in lateral and streamwise direction) have been employed. With an external (hot gas) Mach number of Mam = 0.3 operating conditions are varied in terms of free-stream turbulence intensity (up to 11%), integral length scale at constant turbulence intensity (up to 3.5 hole inlet diameters), and blowing ratio. The temperature ratio is fixed at 0.59 leading to an engine-like density ratio of 1.7. The results indicate that shaped and cylindrical holes exhibit very different reactions to elevated free-stream turbulence levels. For cylindrical holes film cooling effectiveness is reduced with increased turbulence level at low blowing ratios whereas a small gain in effectiveness can be observed at high blowing ratios. For shaped holes, increased turbulence intensity is detrimental even for the largest blowing ratio (M = 2.5). In comparison to the impact of turbulence intensity the effect of varying the integral length scale is found to be of minor importance. Finally the effect of elevated free-stream turbulence in terms of heat transfer coefficients was found to be much more pronounced for the shaped holes.
One viable option to improve cooling methods used for gas turbine blades is to optimize the geometry of the film-cooling hole. To optimize that geometry, effects of the hole geometry on the complex jet-in-crossflow interaction need to be understood. This paper presents a comparison of detailed flowfield measurements for three different single, scaled-up hole geometries, all at a blowing ratio and density ratio of unity. The hole geometries include a round hole, a hole with a laterally expanded exit, and a hole with a forward-laterally expanded exit. In addition to the flowfield measurements for expanded cooling hole geometries being unique to the literature, the testing facility used for these measurements was also unique in that both the external mainstream Mach number (Ma∞ = 0.25) and internal coolant supply Mach number (Mac = 0.3) were nearly matched. Results show that by expanding the exit of the cooling holes, both the penetration of the cooling jet and the intense shear regions are significantly reduced relative to a round hole. Although the peak turbulence level for all three hole geometries was nominally the same, the source of that turbulence was different. The peak turbulence level for both expanded holes was located at the exit of the cooling hole resulting from the expansion angle being too large. The peak turbulence level for the round hole was located downstream of the hole exit where the velocity gradients were very large.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.