Measuring the contrast sensitivity function (CSF) in the periphery of the eye is complicated. The lengthy measurement time precludes all but the most determined subjects. The aim of this study was to implement and evaluate a faster routine based on the quick CSF method (qCSF) but adapted to work in the periphery. Additionally, normative data is presented on neurally limited peripheral CSFs. A peripheral qCSF measurement using 100 trials can be performed in 3 min. The precision and accuracy were tested for three subjects under different conditions (number of trials, peripheral angles, and optical corrections). The precision for estimates of contrast sensitivity at individual spatial frequencies was 0.07 log units when three qCSF measurements of 100 trials each were averaged. Accuracy was estimated by comparing the qCSF results with a more traditional measure of CSF. Average accuracy was 0.08 log units with no systematic error. In the second part of the study, we collected three CSFs of 100 trials for six persons in the 20° nasal, temporal, inferior, and superior visual fields. The measurements were performed in an adaptive optics system running in a continuous closed loop. The Tukey HSD test showed significant differences (p < 0.05) between all fields except between the nasal and the temporal fields. Contrast sensitivity was higher in the horizontal fields, and the inferior field was better than the superior. This modified qCSF method decreases the measurement time significantly and allows otherwise unfeasible studies of the peripheral CSF.
PurposePeripheral resolution acuity depends on the orientation of the stimuli. However, it is uncertain if such a meridional effect also exists for peripheral detection tasks because they are affected by optical errors. Knowledge of the quantitative differences in acuity for different grating orientations is crucial for choosing the appropriate stimuli for evaluations of peripheral resolution and detection tasks. We assessed resolution and detection thresholds for different grating orientations in the peripheral visual field.MethodsResolution and detection thresholds were evaluated for gratings of four different orientations in eight different visual field meridians in the 20-deg visual field in white light. Detection measurements in monochromatic light (543 nm; bandwidth, 10 nm) were also performed to evaluate the effects of chromatic aberration on the meridional effect. A combination of trial lenses and adaptive optics system was used to correct the monochromatic lower- and higher-order aberrations.ResultsFor both resolution and detection tasks, gratings parallel to the visual field meridian had better threshold compared with the perpendicular gratings, whereas the two oblique gratings had similar thresholds. The parallel and perpendicular grating acuity differences for resolution and detection tasks were 0.16 logMAR and 0.11 logMAD, respectively. Elimination of chromatic errors did not affect the meridional preference in detection acuity.ConclusionsSimilar to peripheral resolution, detection also shows a meridional effect that appears to have a neural origin. The threshold difference seen for parallel and perpendicular gratings suggests the use of two oblique gratings as stimuli in alternative forced-choice procedures for peripheral vision evaluation to reduce measurement variation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.