Background: The Glidescope is a novel, portable, reusable video laryngoscope that has provided superior laryngeal visualization to facilitate tracheal intubation, especially in the management of difficult airways. In this study, we aimed to compare the efficacy of the Glidescope (video-laryngoscope) against the Macintosh direct laryngoscope. Methods: Fifty patients were randomly selected via simple randomization using computer-generated random numbers, and sorted into two groups of 25 patients: the Glidescope group and the Macintosh group. We included pediatric patients undergoing cardiac surgery for the repair of congenital heart disease. Those with suspected difficult intubation, preterm babies with low body weight, and patients at risk of aspiration were all excluded. Results: Patients’ baseline demographic and clinical characteristics were found to be comparable in the two groups. The mean intubation time was 24.1 ± 13.6 s in the Glidescope group, as compared to 18.1 ± 5.9 s in the Macintosh group. Blade insertion was easy in 92% and 96% of the patients in the Glidescope and Macintosh groups, respectively. Tracheal intubation was considered easy in 84% of the Glidescope group, compared to 92% of the Macintosh group. There was a statistically significant correlation between the ease of tracheal intubation and the used intubation method (rho = –0.35; P = 0.014). Conclusion: Our findings indicate that the Glidescope can be used as an efficient modality for obtaining successful intubations with no complications. Ease of tracheal intubation was the only outcome that was found to be affected by the used modality. Further investigations with proper sample sizes are needed.
Patients undergoing robotic‐assisted coronary artery bypass grafting are increasing. Several complications have emerged with the increasing use of minimally invasive procedures. We reported a case of spontaneous tension pneumothorax that developed in the ventilated lung during robotic assisted left internal mammary artery harvesting causing severe hemodynamic instability. A sudden rise of airway pressure occurred, and the patient became hypotensive. Immediately, the surgeon was notified to look at the right pleura. Pneumothorax was identified, the right pleura was opened using robotic arms, and the right lung was decompressed. A small emphysematous bulla was identified and stabled. Proper identification of the procedure‐associated complications is essential for timely management. Tension pneumothorax is a potentially fatal complication, especially in patients under positive pressure ventilation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.