, respectively. The random effects model data demonstrated that the F-value calculated was greater than the critical F-value approximately 59 % of the variability in the exposure was due to differences between groups. Based on these finding, the order of probability of the long-term mean exposure exceeding (Z) to the OEL of 10 mg/m 3 for total dust which were in kiln (100%), packing (100%), cement mill (90%), crusher (73%), raw mill (60%) administration (2.3%) and the maintenance parts (0%).
The present study describes a simple and highly selective method for separation, preconcentration and spectrophotometric determination of extremely low concentrations of lead. It is based on flotation of a complex of Pb2+ ions and Alizarin yellow between aqueous and n-hexane interface at pH = 6. The proposed procedure is also applied for determination of lead in both tap water and prepared sea water samples. Beer's Law was obeyed over the concentration range of 3.86 × 10-8 To 8.20 × 10-7 molL-1 (8-170 ngmL-1) with an apparent molar absorptivity of 1.33 × 106 molL-1 cm-1 for a 100 mL aliquot of the water sample. The detection limit (n = 10) was 8.7 × 10-9 molL-1 (1.0 ngmL-1) and the Relative standard deviation (R.S.D), (n = 10) for 7.2 × 10-7 molL-1 (150 ngmL-1) of Pb (II) was 4.36%. A notable advantage of the method is that the determination of Pb (II) is free from the interference of almost all cations and ions found in the environment and waste water samples. The determination of Pb (II) in tap and synthetic seawater samples was also carried out by the present method. The results were satisfactorily comparable so that the applicability of the proposed method was confirmed to the real samples.
A novel and sensitive floatation-spectrophotometric method is presented for determination of trace amounts of thorium in water samples. The method is based on the ion-associated formation between thorium, Eriochrome cyanine R and Brij-35 at pH = 4 media. The complex was floated in the interface of the aqueous phase and n-hexane by vigorous shaking. After removing the aqueous phase the floated particles were dissolved in methanol and the absorbance was measured at 607 nm. The influence of different important parameters such as Eriochrome cyanine R and surfactants concentration, pH, volume of n-hexane, standing time and interfering ions were evaluated. Under optimized conditions the calibration graph was linear in the range of 6–230 ng mL−1 of thorium with a correlation coefficient of 0.9985. The limit of detections (LOD), based on signal to noise ratio (S/N) of 3 was 1.7 ng mL−1. The relative standard deviations for determination of 150 and 30 ng ml−1 of thorium were 3.26 and 4.41%, respectively (n = 10). The method showed a good linearity, recoveries, as well as some advantages such as sensitivity, simplicity, affordability and a high feasibility. The method was successfully applied to determine thorium in different water and urine samples.
The present study describes a simple and highly selective method for separation, preconcentration and spectrophotometric determination of extremely low concentrations of lead. It is based on flotation of a complex of Pb2+ ions and Alizarin yellow between aqueous and n-hexane interface at pH = 6. The proposed procedure is also applied for determination of lead in both tap water and prepared sea water samples. Beer’s Law was obeyed over the concentration range of 3.86 × 10–8 To 8.20 × 10–7 molL−1 (8–170 ngmL−1) with an apparent molar absorptivity of 1.33 × 106 molL−1 cm−1 for a 100 mL aliquot of the water sample. The detection limit (n = 10) was 8.7 × 10–9 molL−1 (1.0 ngmL−1) and the Relative standard deviation (R.S.D), (n = 10) for 7.2 × 10–7 molL−1 (150 ngmL−1) of Pb (II) was 4.36%. A notable advantage of the method is that the determination of Pb (II) is free from the interference of almost all cations and ions found in the environment and waste water samples. The determination of Pb (II) in tap and synthetic seawater samples was also carried out by the present method. The results were satisfactorily comparable so that the applicability of the proposed method was confirmed to the real samples.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.