BackgroundThe pubic region is often involved in accidental hot water or soup-spill burns. Most of these wounds are superficial partial thickness burns. Due to their proximity to the urinary system, as well as vaginal and anal openings, these burns are easily contaminated. Daily dressings are routinely prescribed as the sole treatment. The cumbersome dressing process is uncomfortable and embarrassing for patients. Biobrane™ is a bilayered biosynthetic dressing. Its coverage of superficial partial thickness burns promotes wound healing and allows one-time application.Case presentationsWe report two patients who suffered superficial dermal burns over their pubic region. One patient had 23% total body surface area (TBSA) burns over her lower abdomen, both thighs and pubic region. The second patient had 10% TBSA burns that involved her perineum and the medial sides of both thighs and buttocks. Both were managed with the standard resuscitation protocol in the initial phase. Their burn injuries were managed by shaving, Foley catheterization and Biobrane™ coverage. Their wounds healed uneventfully without complications. Full epithelization was achieved by post-operative day seven. Both patients consented to medical photography and academic publication.ConclusionShaving and catheterization improved the hygiene of the burns of the pubic area. The Biobrane™ method circumvents the need of regular dressing changes, eliminating the pain due to dressing changes and preserving patient dignity.
We tested the tensile strength of the proximal juncture of tendon grafts with Pulvertaft tendon repairs in 18 cadaveric digital flexor tendons. These tendons were divided into three groups of six: single, two, or three weaves. Each of the interlacing weaves was secured with eight anchoring sutures. The specimens were loaded in a biomechanical tester until failure. The ultimate tensile strength did not show any significant differences across all three groups with statistical power of 0.77. The mean tendon elongation before repair failure showed significant difference at 10 mm (standard deviation (SD) 2), 16 mm (SD 3), and 15 mm (SD 3), respectively. All specimens failed by intra-tendinous pull-out of the weaves. We conclude that the two-weave Pulvertaft construct demonstrated comparable tensile strength to three weaves and tendon elongation was similar when two or three weaves were used.
Background: Surgical stabilization of rib fractures is an established form of treatment for complex rib fractures. Plate fixation with bicortical screws placement can cause injury to intra-thoracic organs and pleural irritation from protruding screw tips. The aim of this study is to compare the biomechanical properties of monocortical and bicortical plate fixation for rib fractures using a locking plate system.Methods: Ten pairs of fresh-frozen cadaveric ribs were harvested. Native ribs were mounted onto a biomechanical tester and statically loaded to failure to induce a rib fracture. The native stiffness of the rib was measured. Next, the ribs were stabilized using the Synthes MatrixRIB (Johnson & Johnson, USA) locking plate. Left-sided ribs were fixed in a bicortical manner and right-sided ribs were fixed in a monocortical manner. The repaired ribs were subjected to cyclic loading of 50,000 cycles between 2 to 6 N to simulate physiological respiration, followed by static loading at a rate of 10 N/min until failure. The pre and postrepaired stiffness were measured. A high-speed camera was used to record the mechanism of failure. Results: One left-sided rib was omitted from the study because the fracture occurred at the drill hole site.Left-sided ribs demonstrated a mean native stiffness of 10.0 N/mm (SD 3.71) and right-sided 11.92 N/mm (SD 3.57). After plate fixation, pre and post cyclic stiffness was 3.32 N/mm (SD 1.21) and 4.41 N/mm (SD 3.29) for the bicortical group; 3.14 N/mm (SD 1.24) and 3.91 N/mm (SD 1.98) for the monocortical group.There is no statistical difference found between the two groups (P=0.872). Conclusions: Our results show that there is no difference in stability between monocortical and bicortical fixation for rib fractures using a locking plate system. Monocortical fixation is recommended to avoid potential complications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.