Objective. Given current clinical interest in vagus nerve stimulation (VNS), there are surprisingly few studies characterizing the anatomy of the vagus nerve in large animal models as it pertains to on-and off-target engagement of local fibers. We sought to address this gap by evaluating vagal anatomy in the pig, whose vagus nerve organization and size approximates the human vagus nerve. Approach. Here we combined microdissection, histology, and immunohistochemistry to provide data on key features across the cervical vagus nerve in a swine model, and compare our results to other animal models (mouse, rat, dog, non-human primate) and humans. Main results. In a swine model we quantified the nerve diameter, number and diameter of fascicles, and distance of fascicles from the epineural surface where stimulating electrodes are placed. We also characterized the relative locations of the superior and recurrent laryngeal branches of the vagus nerve that have been implicated in therapy limiting side effects with common electrode placement. We identified key variants across the cohort that may be important for VNS with respect to changing sympathetic/parasympathetic tone, such as cross-connections to the sympathetic trunk. We discovered that cell bodies of pseudo-unipolar cells aggregate together to form a very distinct grouping within the nodose ganglion. This distinct grouping gives rise to a larger number of smaller fascicles as one moves caudally down the vagus nerve. This often leads to a distinct bimodal organization, or ‘vagotopy’. This vagotopy was supported by immunohistochemistry where approximately half of the fascicles were immunoreactive for choline acetyltransferase, and reactive fascicles were generally grouped in one half of the nerve. Significance. The vagotopy observed via histology may be advantageous to exploit in design of electrodes/stimulation paradigms. We also placed our data in context of historic and recent histology spanning multiple models, thus providing a comprehensive resource to understand similarities and differences across species.
Given current clinical interest in vagus nerve stimulation, there are surprisingly few studies characterizing the anatomy of the vagus nerve in large animal models as it pertains to on-and off-target engagement of local fibers. We sought to address this gap by evaluating vagal anatomy in the domestic pig, whose vagus nerve organization and size approximates the human cervical vagus nerve. We provide data on key features across the cervical vagus nerve including diameter, number and diameter of fascicles, and distance of fascicles from the epineural surface where stimulating electrodes are placed. We also characterized the relative locations of the superior and recurrent laryngeal branches of the vagus nerve that have been implicated in therapy limiting side effects with common electrode placement. We identified key variants across the cohort that may be important for vagus nerve stimulation with respect to changing sympathetic/parasympathetic tone, such as cross-connections to the sympathetic trunk. We discovered that cell bodies of pseudo-unipolar cells aggregate together to form a very distinct grouping within the nodose ganglion. This distinct grouping gives rise to a larger number of smaller fascicles as one moves caudally down the cervical vagus nerve. This often leads to a distinct bimodal organization, or ‘vagotopy’ that may be advantageous to exploit in design of electrodes/stimulation paradigms. Finally, we placed our data in context of historic and recent histology spanning mouse, rat, canine, pig, non-human primate and human models, thus providing a comprehensive resource to understand similarities and differences across species.
In in vivo tissue engineering, many implanted cells die because of hypoxic conditions immediately postimplantation. The aim of this study was to determine whether delayed myoblast implantation, at day 4 or 7, improves myoblast survival compared with implantation at day 0 in an in vivo arterio-venous loop (AB loop) chamber model. In adult inbred Sprague-Dawley rats, an AB loop was inserted into a plastic chamber (day 0). In Group I, day 0, two million DiI-labeled (neonatal inbred) myoblasts were implanted around the AB loop. In Groups II and III, day 0, the AB loop was created and inserted into a novel delayed cell seeding chamber, and 4 (Group II) or 7 days (Group III) later the delay chamber was seeded with 2 million DiI-labeled myoblasts. Constructs were harvested 7-day postmyoblast implantation, for morphometric determination of DiI/DAPI-positive myoblasts/mm(2), and percent vascular volume on Griffonia simplicifolia lectin (endothelial cell marker)-labeled tissue sections. Control (nonmyoblast seeded) and experimental (myoblast seeded) constructs demonstrated similar capillary and tissue growth patterns. DiI/DAPI-labeled myoblasts/mm(2) appeared in similar numbers in constructs implanted at days 0 and 4, but increased markedly in day-7 implanted constructs. The percent vascular volume increased significantly (p = 0.03) over time. A positive correlation existed between myoblast survival and construct vascularity (p = 0.017). In conclusion, delaying myoblast implantation to 7-day postconstruct assembly, when new capillary growth is well established, significantly correlates with increased myoblast survival and indicates that cell seeding in regenerative procedures should always occur into an established vascular bed.
The Amicus Separator provided satisfactory platelet yields and collection efficiency, with shorter collection times than did the Spectra LRS, and it white cell-reduced components without filtration.
Liver tissue engineering is hampered by poor implanted cell survival due to inadequate vascularization and cell-cell/cell-matrix interactions. Here, we use liver progenitor cell (LPC) spheroids to enhance cell-cell/cell-matrix interactions, with implantation into an angiogenic in vivo mouse chamber. Spheroids were generated in vitro in methylcellulose medium. Day 2 spheroids were optimal for implantation (22,407 +/-645 cells/spheroid), demonstrating maximal proliferation (Ki67 immunolabeling) and minimal apoptosis (caspase-3 immunolabelling). In vivo chambers established bilaterally on epigastric vessels of immunodeficient mice were implanted with equivalent numbers of LPCs as a cell suspension (200,000 cells), or spheroids (9 spheroids). At day 14, a trend of increased LPC survival was observed in spheroid-implanted chambers [pan-cytokeratin (panCK+) cells, p = 0.38, 2.4 fold increase)], with significantly increased differentiation [cytokeratin 18 (CK18+) cells, p < 0.002, 5.1 fold increase)] compared to cell suspension-implanted chambers. At day 45, both measures were significantly increased in spheroid-implanted chambers (panCK, p < 0.006, 16 fold increase) (CK18, p < 0.019, 6 fold increase). Hepatic acini/plates of CK18 + cells expressed hepatocyte nuclear factor 4-α and β-catenin, indicating ongoing hepatic differentiation. Spheroid cell-delivery significantly increased LPC survival and differentiation compared to conventional cell suspensions. This LPC spheroid/vascularized chamber model has clinical potential to generate three-dimensional vascularized liver tissue for liver replacement.
Isolated mouse LSECs express a panel of vascular-related cell markers and demonstrate substantial vascular capillary-forming ability in vitro and in vivo. Their production of liver growth factors VEGF-A, VEGF-C and HGF enable these cells to exert a growth stimulus post-transplantation on the in vivo host-derived capillary bed, reinforcing their pro-regenerative capabilities for liver tissue engineering studies.
Since the 1940s electrocorticography (ECoG) devices and, more recently, in the last decade, micro-electrocorticography (µECoG) cortical electrode arrays were used for a wide set of experimental and clinical applications, such as epilepsy localization and brain–computer interface (BCI) technologies. Miniaturized implantable µECoG devices have the advantage of providing greater-density neural signal acquisition and stimulation capabilities in a minimally invasive fashion. An increased spatial resolution of the µECoG array will be useful for greater specificity diagnosis and treatment of neuronal diseases and the advancement of basic neuroscience and BCI research. In this review, recent achievements of ECoG and µECoG are discussed. The electrode configurations and varying material choices used to design µECoG arrays are discussed, including advantages and disadvantages of µECoG technology compared to electroencephalography (EEG), ECoG, and intracortical electrode arrays. Electrode materials that are the primary focus include platinum, iridium oxide, poly(3,4-ethylenedioxythiophene) (PEDOT), indium tin oxide (ITO), and graphene. We discuss the biological immune response to µECoG devices compared to other electrode array types, the role of µECoG in clinical pathology, and brain–computer interface technology. The information presented in this review will be helpful to understand the current status, organize available knowledge, and guide future clinical and research applications of µECoG technologies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.