[1] We present an overview of the theoretical and algorithmic aspects of the Ozone Monitoring Instrument (OMI) aerosol and surface UV algorithms. Aerosol properties are derived from two independent algorithms. The nearUV algorithm makes use of OMI observations in the 350-390 nm spectral region to retrieve information on the absorption capacity of tropospheric aerosols. OMI-derived information on aerosol absorption includes the UV Aerosol Index and absorption optical depth at 388 nm. The other algorithm makes use of the full UV-to-visible OMI spectral coverage to derive spectral aerosol extinction optical depth. OMI surface UV products include erythemally weighted daily dose as well as erythemal dose rate and spectral UV irradiances calculated for local solar noon conditions. The advantages and limitations of the current algorithms are discussed, and a brief summary of several validation and evaluation analysis carried out to assess the current level of uncertainty of these products is presented.
[1] The Dutch-Finnish Ozone Monitoring Instrument (OMI) on board the NASA EOS Aura spacecraft is a nadir viewing spectrometer that measures solar reflected and backscattered light in a selected range of the ultraviolet and visible spectrum. The instrument has a 2600 km wide viewing swath and it is capable of daily, global contiguous mapping. The Finnish Meteorological Institute and NASA Goddard Space Flight Center have developed a surface ultraviolet irradiance algorithm for OMI that produces noontime surface spectral UV irradiance estimates at four wavelengths, noontime erythemal dose rate (UV index), and the erythemal daily dose. The overpass erythemal daily doses derived from OMI data were compared with the daily doses calculated from the ground-based spectral UV measurements from 18 reference instruments. Two alternative methods for the OMI UV algorithm cloud correction were compared: the plane-parallel cloud model method and the method based on Lambertian equivalent reflectivity. The validation results for the two methods showed some differences, but the results do not imply that one method is categorically superior to the other. For flat, snow-free regions with modest loadings of absorbing aerosols or trace gases, the OMI-derived daily erythemal doses have a median overestimation of 0-10%, and some 60 to 80% of the doses are within ±20% from the ground reference. For sites significantly affected by absorbing aerosols or trace gases one expects, and observes, bigger positive bias up to 50%. For high-latitude sites the satellite-derived doses are occasionally up to 50% too small because of unrealistically small climatological surface albedo.
The Ozone Monitoring Instrument (OMI) onboard the NASA Earth Observing System (EOS) Aura spacecraft is a nadir-viewing spectrometer that measures solar reflected and backscattered light in a selected range of the ultraviolet and visible spectrum. The instrument has a 2600-km-wide viewing swath, and it is capable of daily, global contiguous mapping. We developed and implemented a surface ultraviolet (UV) irradiance algorithm for OMI that produces noontime surface spectral UV irradiance estimates at four wavelengths (305, 310, 324, and 380 nm). Additionally, noontime erythemal dose rate and the erythemal daily dose are estimated. The OMI surface UV algorithm inherits from the surface UV algorithm developed by NASA Goddard Space Flight Center for the Total Ozone Mapping Spectrometer (TOMS). The OMI surface UV irradiance products are produced and archived in HDF5-EOS format by Finnish Meteorological Institute. The accuracy of the surface UV estimates depend on UV wavelength and atmospheric and other geolocation specific conditions ranging from 7%to 30%. A postprocessing aerosol correction can be applied at sites with additional ground-based measurements of the aerosol absorption optical thickness. The current OMI surface UV product validation plan is presented.
Abstract. The quality assurance of the two Brewer spectrophotometers of the Finnish Meteorological Institute is discussed in this paper. The complete data processing chain from raw signal to high quality spectra is presented. The quality assurance includes daily maintenance, laboratory characterizations, calculation of long-term spectral responsivity, data processing and quality assessment. The cosine correction of the measurements is based on a new method, and is included in the data processing software. The results showed that the actual cosine correction factor of the two Finnish Brewers can vary between 1.08-1.13 and 1.08-1.12, respectively, depending on the sky radiance distribution and wavelength. The temperature characterization showed a linear temperature dependence between the instruments' internal temperature and the photon counts per cycle, and a temperature correction was used for correcting the measurements. The long-term spectral responsivity was calculated using the time series of several lamps using two slightly different methods. The long-term spectral responsivity was scaled to the irradiance scale of the Helsinki University of Technology (HUT) for the whole of the measurement time -periods 1990-2006 and 1995-2006 for Sodankylä and Jokioinen, respectively. Both Brewers have participated in many international spectroradiometer comparisons, and have shown good stability. The differences between the Brewers and the portable reference spectroradiometer QASUME have been within 5% during
Abstract. Ozone Monitoring Instrument (OMI), launched in July 2004, is dedicated to the monitoring of the Earth's ozone, air quality and climate. OMI is the successor of the Total Ozone Mapping Spectrometer (TOMS) instruments and provides among other atmospheric and radiometric quantities the total column of ozone (TOC), the surface ultraviolet (UV) irradiance at several wavelengths, the erythemal dose rates and the erythemal daily doses. The main objective of this work is to compare OMI data with data from ground-based instruments in order to use OMI products (collection 2) for scientific studies. The Laboratoire d'Optique Atmosphérique (LOA) located in Villeneuve d'Ascq (VdA) in the north of France performs solar UV measurements using a spectroradiometer. The site of Briançon in the French Southern Alps is also equipped with a spectroradiometer operated by Interaction Rayonnement Solaire Atmosphère (IRSA). The OMI total ozone column data is obtained from the OMI-TOMS and OMI-DOAS algorithms. The comparison between the TOC retrieved with ground-based measurements and OMI-TOMS data shows good agreement at both sites for all sky conditions with a relative difference for most of points better than 5%. For OMI-DOAS data, the agreement is generally better than 7% and these data show a significant dependence on solar zenith angle. Comparisons of spectral UV on clear sky conditions are also satisfying with relative differences smaller than 10% except at solar zenith angles larger than 65 • . On the contrary, results of comparCorrespondence to: V. Buchard (buchard@loa.univ-lille1.fr) isons of the erythemal dose rates and erythemal daily doses for clear sky show that OMI overestimates surface UV doses at VdA by about 15% and that on cloudy skies, the bias increases. At Briançon, such a bias is observed if data corresponding to snow-covered surface are excluded.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.