We found LA and RFA to be equally effective. However, RA appears more suited to patients with small HCC nodules and in Child-Pugh class A.
KEYWORDSProstate cancer; Ultrasonography; Real-time elastography.Abstract Aim: To assess the diagnostic gain of transrectal real-time elastography (RTE) compared to transrectal B-mode ultrasonography (US) in the detection of tumors in patients suspected of having prostate cancer. Materials and methods: Eighty-four patients suspected of having prostate cancer on the basis of clinical and biochemical evaluation underwent transrectal US, RTE and transperineal prostate biopsy. Results: Biopsy was considered the gold standard. Analysis related to the total number of patients showed a B-mode US sensitivity of 56%, specificity 80%, positive predictive value (PPV) 70% and negative predictive value (NPV) 67%. Analysis related to the total number of biopsy cores showed sensitivity 33%, specificity 92%, PPV 69% and NPV 73%. In the patientrelated analysis, RTE sensitivity was 51%, specificity 75%, PPV 64% and NPV 64%, while the core-related analysis showed sensitivity 36%, specificity 93%, PPV 72% and NPV 74%. Comparison of B-mode US and RTE diagnostic accuracy in the detection of tumors located in the peripheral zone of the prostate gland showed a significant difference. Analysis related to the total number of biopsy cores harvested in the peripheral zone of the prostate gland showed a B-mode US sensitivity of 48%, specificity 81%, PPV 75% and NPV 58%, whereas RTE achieved the following values: sensitivity 66%, specificity 78%, PPV 77%, and NPV 67%. Conclusions: RTE is a valid addition to B-mode US, and RTE reached a higher accuracy than Bmode US in the evaluation of the peripheral zone of the prostate gland and in the selection of appropriate biopsy sites.Sommario Scopo: Verificare il guadagno diagnostico dell'elastosonografia transrettale realtime (RTE) rispetto alla ecografia transrettale B-mode nel rilievo del tumore prostatico in una popolazione di pazienti con sospetto di neoplasia. Materiali e metodi: Ottantaquattro pazienti con sospetto clinico-laboratoristico di tumore prostatico sono stati valutati mediante ecografia transrettale, elastosonografia e biopsia transperineale. Risultati: L'esame bioptico è stato considerato lo standard di riferimento. Nella valutazione per paziente, la sensibilità dell'ecografia B-mode è stata del 56%; la specificità dell'80%; il valore predittivo positivo (VPP) del 70%, il valore predittivo negativo (VPN) del 67%. Nella valutazione sul totale dei prelievi bioptici la sensibilità è stata del 33%, la specificità del 92%, il VPP del 69%, il VPN del 73%. La RTE ha ottenuto i seguenti risultati nella valutazione per paziente: sensibilità 51%, specificità 75%, VPP 64% e VPN 64%. Nella valutazione sul totale dei prelievi bioptici: sensibilità 36%, specificità 93%, VPP 72%, VPN 74%. Confrontando i valori di accuratezza dell'ecografia B-mode e della RTE per i tumori della zona periferica, è stata trovata una differenza significativa. Nella valutazione sul totale dei prelievi bioptici della zona periferica la sensibilità dell'ecografia B-mode è stata del 48%, la specificità dell'81%, il VPP d...
US is the first-line technique for examination of muscle injuries. MRI is able to reveal lesions that may be missed at US and provide a more accurate assessment of site and extent of injury.
KEYWORDSThyroid; Ultrasound; Elastosonography; Contrast agent.Abstract Aim: To evaluate the usefulness of ultrasound (US) using contrast agent and elastosonography in the characterization of thyroid nodules. Materials and methods: From November 2006 to July 2007, 23 patients with single thyroid nodules underwent B-mode US and power Doppler, US examination using contrast agent, elastosonography and fine needle aspiration cytology (FNAC). Sixteen patients underwent thyroidectomy. Results: The 23 nodules included 14 benign and 9 malignant lesions. Analysis of time/intensity curves showed that wash-in (8.8 AE 1.3 vs 12.1 AE 2.6 s; p Z 0.002, t-test) and peak enhancement (15.3 AE 4.6 vs 22.2 AE 3.9 s; p Z 0.001, t-test) occurred significantly earlier in the malignant nodules than in the benign nodules. Wash-out was monophasic in 70% of benign nodules, but in none of the malignant nodules; polyphasic in 30% of benign nodules and in 100% of malignant nodules. Polyphasic wash-out showed a statistically significant association with malignancy (p Z 0.0007, c 2 ). Polyphasic wash-out yielded a sensitivity of 100%, specificity of 71%, positive predictive value (PPV) of 69%, negative predictive value (NPV) of 100% and diagnostic accuracy of 83%. In 78% of the benign nodules (11/14) elastosonographic patterns was 1e2 (elevated elasticity); in 88% of the malignant nodules (8/9) elastosonographic patterns was 3e4 (reduced elasticity). Elastosonography yielded a sensitivity of 88%, specificity of 78%, PPV of 72%, NPV of 91% and diagnostic accuracy of 82%. Elastosonographic patterns 3e4 is associated with malignancy (p Z 0.001, c 2 ). Conclusion: US using contrast agent and elastosonography can be a useful diagnostic tool in the evaluation of single thyroid nodules, particularly when FNAC result is non-diagnostic or suggests a follicular lesion, and in nodules <1 cm.Sommario Scopo: Valutare l'utilità dell'ecografia con ecoamplificatore e dell'elastosonografia nella caratterizzazione del nodulo tiroideo. contrasto, elastosonografia e FNAC (Fine Needle Aspiration Citology). Sedici pazienti sono stati sottoposti a tiroidectomia. Risultati: I 23 noduli studiati comprendevano 14 lesioni benigne e 9 maligne. Alla valutazione delle curve intensità/tempo le lesioni maligne presentavano un tempo di wash-in (8,8 AE 1,3 vs 12,1 AE 2,6 secondi; p Z 0,002, t-test) e un tempo di picco (15,3 AE 4,6 vs 22,2 AE 3,9 secondi; p Z 0,001, t-test) significativamente più precoci rispetto alle lesioni benigne. La fase di wash-out presentava andamento monofasico nel 70% dei noduli benigni e in nessuno dei maligni; polifasico nel 30% dei noduli benigni e nel 100% dei maligni. L'andamento polifasico è associato in maniera statisticamente significativa (p Z 0,0007, c 2 ) alla malignità. L'andamento polifasico ha mostrato sensibilità del 100%, specificità del 71%, VPP (valore predittivo positivo) del 69%, VPN (valore predittivo negativo) del 100% e accuratezza diagnostica dell'83%. Nel 78% (11/14) dei noduli benigni sono stati rilevati i pattern elastosonogr...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.