Abstract-The LHCb experiment at CERN will have an Event Filter Farm (EFF) composed of 2000 CPUs. These machines will form a pool of 50 sub-farms with 30 to 40 nodes each, running a large amount of High Level Trigger (HLT) tasks in parallel. Although these tasks are identical algorithms, they can run at the same time being configured with different parameters, such as run type (Physics, Cosmics, Test, etc.) or with different subdetectors (partitions). The HLT is the second of the two trigger levels in LHCb. Its selection algorithms reduce the incoming data rate of 1 MHz to an output rate of 2 kHz. Selected events are sent for mass storage and subsequent offline reconstruction and analysis. These trigger processes running online are based on the same software framework as the algorithms for offline analysis (Gaudi). The control of the trigger farm was developed with an industrial SCADA system (PVSS) which is used throughout the Experiment Control System (ECS). The HLT algorithms are handled by the ECS like hardware devices, for instance, high voltage channels. The integration of the HLT controls in the overall ECS, which is modeled as finite state machines, will be presented.Index Terms-Experiment control system (ECS), finite state machine (FSM), gaucho, high level trigger (HLT), PVSS.
Abstract-The LHCb experiment at CERN will have an Event Filter Farm (EFF) composed of 2000 CPUs. These machines will form a pool of 50 sub-farms with 30 to 40 nodes each, running a large amount of High Level Trigger (HLT) tasks in parallel. Although these tasks are identical algorithms, they can run at the same time being configured with different parameters, such as run type (Physics, Cosmics, Test, etc.) or with different subdetectors (partitions). The HLT is the second of the two trigger levels in LHCb. Its selection algorithms reduce the incoming data rate of 1 MHz to an output rate of 2 kHz. Selected events are sent for mass storage and subsequent offline reconstruction and analysis. These trigger processes running online are based on the same software framework as the algorithms for offline analysis (Gaudi). The control of the trigger farm was developed with an industrial SCADA system (PVSS) which is used throughout the Experiment Control System (ECS). The HLT algorithms are handled by the ECS like hardware devices, for instance, high voltage channels. The integration of the HLT controls in the overall ECS, which is modeled as finite state machines, will be presented.Index Terms-Experiment control system (ECS), finite state machine (FSM), gaucho, high level trigger (HLT), PVSS.
No abstract
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.