Currently spin waves are considered for computation and data processing as an alternative to charge currents. Generation of spin waves by ultrashort laser pulses provides several important advances with respect to conventional approaches using microwaves. In particular, focused laser spot works as a point source for spin waves and allows for directional control of spin waves and switching between their different types. For further progress in this direction it is important to manipulate with the spectrum of the optically generated spin waves. Here we tackle this problem by launching spin waves by a sequence of femtosecond laser pulses with pulse interval much shorter than the relaxation time of the magnetization oscillations. This leads to the cumulative phenomenon and allows us to generate magnons in a specific narrow range of wavenumbers. The wavelength of spin waves can be tuned from 15 μm to hundreds of microns by sweeping the external magnetic field by only 10 Oe or by slight variation of the pulse repetition rate. Our findings expand the capabilities of the optical spin pump-probe technique and provide a new method for the spin wave generation and control.
Magnetometry and visualization of very small magnetic fields are vital for a large variety of the areas ranging from magnetocardiography and encephalography to nondistractive defectoscopy and ultra-low-frequency communications. It is very advantageous to measure magnetic fields using exchange-coupled spins in magnetically ordered media (flux-gate magnetometry).Here we introduce and demonstrate a novel concept of a roomtemperature magnetoplasmonic magnetic field sensor with high sensitivity and spatial resolution. It is based on the advanced fluxgate technique in which magnetization of the fully saturated magnetic film is rotated in the film plane and the monitored magnetic field is measured by detecting variation of transmittance through the sensing element: a magnetoplasmonic crystal. The experimental study revealed that such an approach allows one to reach the nT sensitivity level, which was limited by the noise of the laser. Moreover, we propose an approach to improve the sensitivity up to fT/Hz 1/2 and reach micrometer spatial resolution. Therefore, the demonstrated magnetoplasmonic magnetometry method is promising for mapping and visualization of ultrasmall magnetic fields.
Optical impact on the spin system in a magnetically ordered medium provides a unique possibility for local manipulation of magnetization at subpicosecond time scales. One of the mechanisms of the optical manipulation is related to the inverse Faraday effect (IFE). Usually the IFE is observed in crystals and magnetic films on a substrate. Here we demonstrate the IFE induced by fs-laser pulses in the magnetic film inside the magnetophotonic microcavity. Spectral dependence of the IFE on the laser pulse wavelength in the band gap of the magnetophotonic microcavity has a sharp peak leading to a significant enhancement of the IFE. This phenomenon is explained by strong confinement of the electromagnetic energy within the magnetic film. Calculated near field distribution of the IFE effective magnetic field indicates its subwavelength localization within 30 nm along the film thickness. These excited volumes can be shifted along the sample depth via e.g. changing frequency of the laser pulses. The obtained results open a way for ultrafast optical control of magnetization at subwavelength scales.
Magnetic circular dichroism in the spectral region from 270 to 850 nm and Faraday rotation at the wavelength of 655 nm in ultrathin (1.5-92.8 nm) films prepared by reactive ion beam sputtering of target of nominal composition Bi2.8Y0.2Fe5O12 were studied. The observed effects of the "blue shift," inversion of the signs and change in the intensity of magneto-optical transitions, are discussed. It is demonstrated that all studied nanoscale films reveal magnetic properties-and their composition depends on the method of substrate surface pretreatment.
The concept of vector magneto-optical magnetometry is proposed and experimentally demonstrated. The key element of the vector magnetometer is a transparent high Faraday activity magnetic film with a cubic crystal lattice. Magnetocrystalline anisotropy of the film leads to the three dimensional trajectory of the film magnetization when the magnetization is rotated by the control magnetic field. It makes the magnetization sensitive to all three components of the external magnetic field. This field can be found from the harmonic composition of the Faraday rotation dependence on the azimuth angle of the control magnetic field. The demonstrated vector magnetometer is promising for mapping and visualization of ultra small magnetic fields.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.