The Double Chooz Experiment presents an indication of reactor electron antineutrino disappearance consistent with neutrino oscillations. An observed-to-predicted ratio of events of 0.944 ± 0.016 (stat) ± 0.040 (syst) was obtained in 101 days of running at the Chooz Nuclear Power Plant in France, with two 4.25 GW th reactors. The results were obtained from a single 10 m 3 fiducial volume detector located 1050 m from the two reactor cores. The reactor antineutrino flux prediction used the Bugey4 flux measurement after correction for differences in core composition. The deficit can be interpreted as an indication of a non-zero value of the still unmeasured neutrino mixing parameter sin 2 2θ13. Analyzing both the rate of the prompt positrons and their energy spectrum we find sin 2 2θ13= 0.086 ± 0.041 (stat) ±0.030 (syst), or, at 90% CL, 0.017 < sin 2 2θ13 < 0.16. We report first results of a search for a non-zero neutrino oscillation [1] mixing angle, θ 13 , based on reactor antineutrino disappearance. This is the last of the three neutrino oscillation mixing angles [2,3] for which only upper limits [4,5] are available. The size of θ 13 sets the required sensitivity of long-baseline oscillation experiments attempting to measure CP violation in the neutrino sector or the mass hierarchy.In reactor experiments [6,7] addressing the disappearance ofν e , θ 13 determines the survival probability of electron antineutrinos at the "atmospheric" squaredmass difference, ∆m 2 atm . This probability is given by:where L is the distance from reactor to detector in meters and E the energy of the antineutrino in MeV. The full formula can be found in Ref.[1]. Eq. 1 provides a direct way to measure θ 13 since the only additional input is the well measured value of |∆m 2 atm | = (2.32Other running reactor experiments [9,10] are using the same technique.Electron antineutrinos of < 9 MeV are produced by reactors and detected through inverse beta decay (IBD): ν e + p → e + + n. Detectors based on hydrocarbon liquid scintillators provide the free proton targets. The IBD signature is a coincidence of a prompt positron signal followed by a delayed neutron capture. We present here our first results with a detector located ∼ 1050 m from the two 4.25 GW th thermal power reactors of the Chooz Nuclear Power Plant and under a 300 MWE rock overburden. The analysis is based on 101 days of data including 16 days with one reactor off and one day with both reactors off.The antineutrino flux of each reactor depends on its thermal power and, for the four main fissioning isotopes, 235 U, 239 Pu, 238 U, 241 Pu, their fraction of the total fuel content, their energy released per fission, and their fission and capture cross-sections. The fission rates and associated errors were evaluated using two predictive and complementary reactor simulation codes: MURE [17,18] and DRAGON [19]. This allowed a study of the sensitivity to the important reactor parameters (e.g.. thermal power, boron concentration, temperatures and densities). The quality of these simulations...
The Double Chooz experiment has observed 8,249 candidate electron antineutrino events in 227.93 live days with 33.71 GW-ton-years (reactor power × detector mass × livetime) exposure using a 10.3 m 3 fiducial volume detector located at 1050 m from the reactor cores of the Chooz nuclear power plant in France. The expectation in case of θ13= 0 is 8,937 events. The deficit is interpreted as evidence of electron antineutrino disappearance. From a rate plus spectral shape analysis we find sin 2 2θ13 = 0.109 ± 0.030(stat) ± 0.025(syst). The data exclude the no-oscillation hypothesis at 99.8% CL (2.9σ).
Originally designed as a new nuclear reactor monitoring device, the Nucifer detector has successfully detected its first neutrinos. We provide the second shortest baseline measurement of the reactor neutrino flux. The detection of electron antineutrinos emitted in the decay chains of the fission products, combined with reactor core simulations, provides a new tool to assess both the thermal power and the fissile content of the whole nuclear core and could be used by the International Agency for Atomic Energy (IAEA) to enhance the Safeguards of civil nuclear reactors. Deployed at only 7.2 m away from the compact Osiris research reactor core (70 MW) operating at the Saclay research centre of the French Alternative Energies and Atomic Energy Commission (CEA), the experiment also exhibits a well-suited configuration to search for a new short baseline oscillation. We report the first results of the Nucifer experiment, describing the performances of the ∼ 0.85 m 3 detector remotely operating at a shallow depth equivalent to ∼ 12 m of water and under intense background radiation conditions. Based on 145 (106) days of data with reactor ON (OFF), leading to the detection of an estimated 40 760 νe, the mean number of detected antineutrinos is 281 ± 7(stat) ± 18(syst) νe/day, in agreement with the prediction 277 ± 23 νe/day. Due to the large background no conclusive results on the existence of light sterile neutrinos could be derived, however. As a first societal application we quantify how antineutrinos could be used for the Plutonium Management and Disposition Agreement. arXiv:1509.05610v4 [physics.ins-det]
A: The S experiment is a very short baseline reactor antineutrino experiment aiming at testing the hypothesis of light sterile neutrinos as an explanation of the deficit of the observed neutrino interaction rate with respect to the predicted rate, known as the Reactor Antineutrino Anomaly. The detector center is located 10 m away from the compact, highly 235 U enriched core of the research nuclear reactor of the Institut Laue Langevin in Grenoble, France. This paper describes the S site, the detector components and associated shielding designed to suppress the external sources of background which were characterized on site. It reports the performances in terms of detector response and energy reconstruction.
The Double Chooz collaboration presents a measurement of the neutrino mixing angle θ 13 using reactor ν e observed via the inverse beta decay reaction in which the neutron is captured on hydrogen. This measurement is based on 462.72 live days data, approximately twice as much data as in the previous such analysis, collected with a detector positioned at an average distance of 1050 m from two reactor cores. Several novel techniques have been developed to achieve significant reductions of the backgrounds and systematic uncertainties. Accidental coincidences, the dominant background in this analysis, are suppressed by more than an order of magnitude with respect to our previous publication by a multi-variate analysis. These improvements demonstrate the capability of precise measurement of reactor ν e without gadolinium loading. Spectral distortions from the ν e reactor flux predictions previously reported with the neutron capture on gadolinium events are confirmed in the independent data sample presented here. A value of sin 2 2θ 13 = 0.095 +0.038 −0.039 (stat+syst) is obtained from a fit to the observed event rate as a function of the reactor power, a method insensitive to the energy spectrum shape. A simultaneous fit of the hydrogen capture events and of the gadolinium capture events yields a measurement of sin 2 2θ 13 = 0.088 ± 0.033(stat+syst).
The spectral shape of reactor antineutrinos measured in recent experiments shows anomalies in comparison to neutrino reference spectra. New precision measurements of the reactor neutrino spectra as well as more complete input in nuclear data bases are needed to resolve the observed discrepancies between models and experimental results. This article proposes the combination of experiments at reactors which are highly enriched in 235 U with commercial reactors with typically lower enrichment to gain new insights into the origin of the anomalous neutrino spectrum. The presented method clarifies, if the spectral anomaly is either solely or not at all related to the predicted 235 U spectrum. Considering the current improvements of the energy scale uncertainty of present-day experiments, a significance of three sigma and above can be reached. As an example, we discuss the option of a direct comparison of the measured shape in the currently running Double Chooz near detector and the upcoming Stereo experiment. A quantitative feasibility study emphasizes that a precise understanding of the energy scale systematics is a crucial prerequisite in recent and next generation experiments investigating the spectral anomaly.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.