Walking behaviour in amputees with lower-limb loss is absent from shock-absorbing properties. A damper can be used to reduce the impact of ground reaction force (GRF) during heel strikes. Magnetorheological fluid (MRF) damper is deemed the best option for this application as it includes the advantages of both passive and active dampers. An enhanced MRF damper is essential in supplying the appropriate current and damping force levels. Therefore, an energy-efficient design is required to prolong the battery life used by MRF dampers in prosthetic limbs. This paper investigates two fluids of different properties and magnetic particle volume content. A bypass damper was used to observe the response of both fluids. The findings highlighted that an MRF with a higher percentage of solid weight could produce a more significant damping force with a lesser amount of applied current. This work presents a simulation study on implementing the energy-efficient MRF damper utilizing a Fuzzy-PID controller in a prosthetic limb.
The normal penetration of armor-piercing projectiles into single and multi-layered steel plates has been investigated. An experimental program has been conducted to study the effect of spaced and in-contact layered targets on their ballistic resistance. Armor piercing projectiles with caliber of 7.62 mm were fired against a series of single and multi-layered steel targets. The projectile impact velocities were ranged from 300-600 m/s, whereas the total thicknesses of the tested single, spaced and in-contact layered steel targets were 3 mm. The penetration process of different tested target configurations has been simulated using Autodayn-2D hydrocode.The experimental measurements of the present work were used to discuss the effect of impact velocity, target configurations and number of layers of different spaced and in-contact layered steel targets on their ballistic resistance. In addition, the post-firing examination of the tested targets over the used impact velocity range showed that the single and each layer of spaced and in-contact laminated steel targets were failed by petalling. Finally, the obtained experimental measurements were compared with the corresponding numerical results of Autodyn-2D hydrocode, good agreement was generally obtained.
Magnetorheological elastomers (MREs) are smart viscoelastic materials in which their physical properties can be altered when subjected to a varying magnetic field strength. MREs consist of an elastomeric matrix mixed with magnetic particles, typically carbonyl iron particles (CIPs). The magnetic field-responsive property of MREs have led to their wide exposure in research. The potential development and commercialization of MRE-based devices requires extensive investigation to identify the essential factors that can affect their properties. For this reason, this research aims to investigate the impact of CIPs’ type, concentration and coating on the rheological and mechanical properties of MREs. Isotropic MREs are fabricated with four different CIP compositions differing between hard or soft, and coated or uncoated samples. Each MRE composition have three different concentrations, which is 5%, 10%, and 20% by volume. The dynamic properties of the fabricated samples are tested by compression oscillations on a dynamic mechanical analyzer (DMA). Frequency and strain dependent measurements are performed to obtain the storage and loss modulus under different excitation frequencies and strain amplitudes. The emphasis is on the magnetorheological (MR) effect and the Payne effect which are an intrinsic characteristics of MREs. The effect of the CIPs’ type, coating, and concentration on the MR and Payne effect of MREs are elucidated. Overall, it is observed that, the storage and loss modulus exhibit a strong dependence on both the frequency excitations and the strain amplitudes. Samples with hard and coated CIPs tend to have a higher MR effect than other samples. A decrease in the storage modulus and non-monotonous behavior of the loss modulus with increasing strain amplitude are observed, indicating the Payne effect. The results of this study can aid in the characterization of MREs and the proper selection of CIPs grades based on the application.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.