The aim of this study was to evaluate the efficacy of swim-up, PureSperm gradient centrifugation and glass-wool filtration methods for semen preparation and to assess the possible enhancement of the quality of the subpopulation of spermatozoa in terms of sperm concentration, morphology and chromatin condensation. Moreover, to determine the effect of this semen processing technique on the clinical outcome after in vitro fertilization embryo transfer (IVF-ET). A total of 180 semen samples of patients' husbands who were undergoing IVF therapy were prepared by swim-up (G1, n = 60), PureSperm gradient centrifugation (G2, n=60) or glass-wool (G3, n=60) methods. Chromatin condensation was assessed by Chromomycin (CMA3), whereas sperm morphology was evaluated according to strict criteria. In all three semen processing methods, the percentage of chromatin condensed and morphologically normal spermatozoa was higher after semen processing in comparison with native semen samples. The proportion of normal chromatin condensed spermatozoa prepared in glass-wool filtration was significantly higher than that in swim-up (G.I, p=0.02) or PureSperm (G.II, p=0.001). In addition semen processing with PureSperm yields significantly a higher percentage of morphologically normal spermatozoa than swim-up (p < 0.001) or glass-wool method (p < 0.002). However, the fertilization, implantation and pregnancy rates, in turn were similar in all semen preparation methods. In conclusion, PureSperm gradient centrifugation yields a higher percentage of morphologically normal spermatozoa than shown in traditional swim-up or glass-wool filtration. However, the percentage of chromatin condensed spermatozoa was significantly higher after semen processing via glass-wool in comparison with the other two methods. Nevertheless, there were no significant difference in the fertilization, implantation and pregnancy rates of sperm prepared by means of swim-up, PureSperm or glass-wool filtration. Therefore, glass-wool filtration should be recommended as the first choice for semen preparation for Intracytoplasmic sperm injection (ICSI) technique as the natural selection is bypassed. Whereas, swim-up and PureSperm should be used for semen processing in IVF programme.
The aim of this study was to evaluate the ef®cacy of swim-up, PureSperm Ò gradient centrifugation and glass±wool ®ltration methods for semen preparation and to assess the possible enhancement of the quality of the subpopulation of spermatozoa in terms of sperm concentration, morphology and chromatin condensation. Moreover, to determine the effect of this semen processing technique on the clinical outcome after in vitro fertilization embryo transfer (IVF-ET).A total of 180 semen samples of patients' husbands who were undergoing IVF therapy were prepared by swim-up (G1, n 60), PureSperm Ò gradient centrifugation (G2, n 60) or glass±wool (G3, n 60) methods. Chromatin condensation was assessed by Chromomycin (CMA3), whereas sperm morphology was evaluated according to strict criteria. In all three semen processing methods, the percentage of chromatin condensed and morphologically normal spermatozoa was higher after semen processing in comparison with native semen samples. The proportion of normal chromatin condensed spermatozoa prepared in glass±wool ®ltration was signi®cantly higher than that in swim-up (G.I, p 0.02) or PureSperm Ò (G.II, p 0.001). In addition semen processing with PureSperm Ò yields signi®cantly a higher percentage of morphologically normal spermatozoa than swim-up (p < 0.001) or glass±wool method (p < 0.002). However, the fertilization, implantation and pregnancy rates, in turn were similar in all semen preparation methods.In conclusion, PureSperm Ò gradient centrifugation yields a higher percentage of morphologically normal spermatozoa than shown in traditional swim-up or glass±wool ®ltration. However, the percentage of chromatin condensed spermatozoa was signi®-cantly higher after semen processing via glass±wool in comparison with the other two methods.Nevertheless, there were no signi®cant difference in the fertilization, implantation and pregnancy rates of sperm prepared by means of swim-up, PureSperm Ò or glass±wool ®ltration. Therefore, glass±wool ®ltration should be recommended as the ®rst choice for semen preparation for Intracytoplasmic sperm injection (ICSI) technique as the natural selection is bypassed. Whereas, swim-up and PureSperm should be used for semen processing in IVF programme.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.