We report on a micro-gravity survey of the laboratories where the LNE's watt balance experiment is being conducted, including the characterization of the Scintrex CG-5 relative gravimeter used for this study. The results of the survey are compared with a model of the gravity field generated by the local mass distribution. The ultimate goal is to transfer an absolute measurement of g from one room to another with minimal uncertainty.
The Sixth International Comparison of Absolute Gravimeters was held from 5 June to 28 August 2001 at the Bureau International des Poids et Mesures (BIPM), Sèvres. Seventeen absolute gravimeters were used to make measurements at five sites of the BIPM gravity network. The vertical gravity gradients at the sites and the ties between them were also measured using seventeen relative gravimeters. For the first time the ties were also measured using absolute gravimeters. Various methods of processing the absolute and relative data were tested to calculate the results. The final results of ICAG-2001 are presented. The acceleration due to gravity at a height of 0.90 m is given as (980 925 701.2 ± 5.5) µGal* and (980 928 018.8 ± 5.5) µGal for sites A and B, respectively,
Since the 1st International Comparison of Absolute Gravimeters (ICAG) and accompanying Relative Gravity Campaign (RGC) held at the BIPM in 1981, repeated ICAG-RGCs have been organized every four years. A total of 19 absolute gravimeters (AG) and 15 relative gravimeters (RG) participated in the 7th ICAG-RGC, which took place in 2005. Co-located absolute and relative gravity measurements as well as precision levelling measurements were carried out.The final version of the absolute g values of the 7th ICAG has been officially released recently. This paper is the final report of the 7th RGC and replaces the preliminary results published earlier. It covers the organization of the RGC and the data processing, analyses RG behaviour, computes g, δg and OAG (offset of AG) and discusses their uncertainties. In preparation for the BIPM key comparison ICAG-2009, a standard data-processing procedure has been developed and installed in the BIPM ICAG-RGC software package, GraviSoft. This was used for the final data processing.
On the occasion of the fourth International Comparison of Absolute Gravimeters carried out at Sèvres in 1994 an extensive series of microgravimetric measurements was organized. In total, fifteen LaCoste, four Scintrex CG-3M and one Sodin gravimeter measured, within a small network, vertical gravity gradients and a calibration baseline. The results show that the accuracy for single instruments is in the range of 3 μGal to 5 μGal in gravity difference, for the Scintrex and the LaCoste meters. Data from the series were also used to intercompare different ways of calibrating the gravimeter electrostatic feedback systems. The calibration platform of the Institut für Angewandte Geodäsie, (IFAG), Frankfurt, and the calibration lift of the Observatoire Royal de Belgique (ORB) were installed at Sèvres and the results compared with those for the calibration line. This paper gives the first results and a review of the techniques used.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.