High survival rates have been reported for the uncemented CLS Spotorno stem up to 10 years. To confirm survival at longer followup we report the minimum 15-year (mean, 17 years; range, 15-20 years) for 257 hips using this stem. We retrospectively evaluated the clinical and radiographic results of all 326 patients (354 THAs) operated between 1985 and 1989. The patients had a mean age of 57 years using an uncemented grit-blasted, tapered titanium femoral stem. Eighty-six patients (89 hips) died and eight patients (eight hips) were lost to followup, leaving 240 patients (257 hips) for evaluation. The femoral component was revised in 35 hips: eight for infection, nine for periprosthetic fracture, one for traumatic loosening, and 17 for aseptic loosening. Survival of the stem was 88% at 17 years (95% confidence interval, 84%-92%), and survival with femoral revision for aseptic loosening as an end point was 94% (95% confidence interval, 91%-97%). The median Harris hip score at followup was 80 points. No thigh pain was reported. Small osteolytic lesions (< 1 cm(2)) were found in the proximal Gruen zones (1 or/and 7) in 28 hips (15%). No distal femoral osteolysis was found. The long-term survival with this type of femoral component remains high in the second decade.
After a minimum duration of follow-up of fifteen years, the survival of this type of femoral component is excellent in individuals younger than fifty-five years. The main mode of stem failure was a periprosthetic fracture due to trauma, or late aseptic loosening in a small percentage of the hips in which the femoral implant was undersized. The high rate of failure of the acetabular components was attributable to a poor design that is no longer in use.
Background and purposeVariations in hip anatomy limit the femoral canal fit of standard uncemented hip stems. In addition, there are still issues with leg length discrepancy and offset reconstruction, potentially resulting in impingement, dislocation, and wear. Modular stems with different shapes for femoral canal fit and multiple neck options may improve the outcome and reduce complications.Patients and methods173 patients (190 hips) received an uncemented THA with 1 of 2 different stem shapes for canal fit and a modular neck for stature-specific hip reconstruction. Median follow-up time was 9 (7–13) years. During the follow-up period, 20 patients died (22 hips) and 12 patients (13 hips) were lost to follow-up. 155 hips were available for evaluation, including clinical and radiological outcome.Results1 stem was revised for a periprosthetic fracture following trauma; 10 cups and 2 modular necks were revised (1 for breakage and 1 during cup revision). At 10 years, stem survival was 100%, modular neck survival was 99% (CI: 95–100), and cup survival was 94% (CI: 87–97). No leg length discrepancies were measured in 96% of cases. Offset with anatomic lateralization was achieved in 98%. Median Harris hip score was 94 (47–100) and median Merle d'Aubigné score was 16 (10–18). Relevant radiolucent lines and osteolysis were not found.InterpretationThe uncemented modular neck, dual-stem system used in this series allows accurate reconstruction of the joint by adapting the implant to the needs of the patient. This may improve the outcome of primary THA, which is supported by the results of this medium-term follow-up evaluation.
In the 1970s, high failure rates of cemented acetabular components, especially in young patients, in the middle-and long-term prompted a search for alternatives. The Mecring was one of the most popular first generation uncemented, threaded cups widely used in the 1980s for arthroplasty of the hip. First generation threaded cups commonly had smooth surface treatment and showed unacceptably high failure rates in the midterm. In a consecutive series of 209 patients, 221 threaded uncemented acetabular cups with smooth surface treatment (Mecring) had been implanted in combination with one type of uncemented stem. Patients were followed up clinically and radiographically. The mean time of follow-up was 17 (range 15-20) years. In 91 (41%) hips the acetabular component had been revised or was awaiting revision: two hips for infection and 84 (38%) for aseptic loosening. Five hips were awaiting revision. The survival rate for all revisions including hips awaiting revision was 49% (95% CI: 41-57%) at 17 years. These results support the view that smooth, threaded acetabular components do not provide satisfactory long-term fixation and should be abandoned. Patients with these components must be closely monitored as the failure rate remains high in the long-term.
Uncemented, threaded acetabular components with smooth surface treatment were widely used in continental Europe in the 1970s and 1980s for primary total hip arthroplasty (THA). Previously published studies showed high failure rates in the mid-term. In a consecutive series of 116 patients, 127 threaded cups with smooth surface treatment (Weill cup; Zimmer, Winterthur, Switzerland) were implanted in combination with one type of uncemented stem. Patients were followed up clinically and radiographically. Mean time of follow-up was 17 years (range [15][16][17][18][19][20]. At the time of follow-up, the acetabular component had been revised or was awaiting revision in 30 hips (24%). Two hips were revised for infection and 23 for aseptic loosening. Four polyethylene liners were exchanged because of excessive wear. One hip was awaiting revision. The survival rate for all acetabular revisions including one hip awaiting revision was 75% (95%CI: 65-85%) at 17 years. These results support the view that smooth, threaded acetabular components do not provide satisfactory long-term fixation and should be abandoned. It is important to closely monitor patients with these components as the failure rate remains high in the long-term.
The long-term results with this type of uncemented tapered titanium femoral component after proximal femoral osteotomy remain encouraging and compare favorably to those achieved in patients with regular femoral anatomy.
Please cite this article in press as: Zaoui K, et al. Topographic bone thickness maps to evaluate the intuitive placement of titanium miniplates for nasal prostheses,
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.