The results of a study on gigawatt power pulsed ion beam parameters are presented here. The pulsed ion beam is formed by a diode with an explosive-emission potential electrode, in magnetic self-isolation mode [A. I. Pushkarev, J. I. Isakova, M. S. Saltimakov et al., Phys. Plasmas 17, 013104 (2010)]. The ion current density is 20–40 A/cm2, the energy of the ions is 200–250 keV, and the beam composition is of protons and carbon ions. Experiments have been performed on the TEMP-4M accelerator, set in double-pulse formation mode. To measure the beam parameters, we used a time-of-flight diagnosis. It is shown that the carbon ion current density, formed in a planar diode with graphite potential electrode, is five to seven times higher than the values calculated from the Child–Langmuir ratio. A model of ion current density amplification in a diode with magnetic self-isolation is proposed. The motion of electrons in the anode-cathode gap is simulated using the program CST PARTICLE STUDIO.
The results of an experimental investigation of a magnetically self-insulated effect in an ion diode in bipolar-pulse mode are presented. The investigations were accomplished at the TEMP-4M accelerator by formation of a first negative pulse (100 ns, 150–200 kV) and a second positive pulse (80 ns, 200–300 kV) [G. E. Remnev et al., Surf. Coat. Technol. 114, 206 (1999)]. Plasma behavior in the anode-cathode gap was analyzed according to the current-voltage characteristics of the diode with a time resolution of 0.5 ns. It is shown that during the discrete emissive surface mode, the magnetic field influence on plasma dynamics is slight. During the space charge limitation mode, the current-voltage characteristics of the diode are well-described by the Child–Langmuir ratio. The drift speed of electrons in the diode exceeds 80 mm/ns and the effect of magnetic insulation is insignificant. It was discovered, when plasma formation at the potential electrode is complete and up until the second positive pulse that the plasma speed is constant and equals to 1.3±0.2 cm/μs. After the voltage polarity at the potential electrode changes (second pulse), plasma breakup at the anode-cathode gap takes place. The impedance of the diode begins to increase and, when the total current is more than 30 kA, the diode impedance exceeds the calculated values by more than three times. The energy efficiency and limiting characteristics of the magnetically self-insulated diode are determined.
In this paper we present the analysis of shot to shot reproducibility of the ion beam which is formed by a self-magnetically insulated ion diode with an explosive emission graphite cathode. The experiments were carried out with the TEMP-4M accelerator operating in double-pulse mode: the first pulse is of negative polarity (300-500 ns, 100-150 kV), and this is followed by a second pulse of positive polarity (150 ns, 250-300 kV). The ion current density was 10-70 A/cm(2) depending on the diode geometry. The beam was composed from carbon ions (80%-85%) and protons. It was found that shot to shot variation in the ion current density was about 35%-40%, whilst the diode voltage and current were comparatively stable with the variation limited to no more than 10%. It was shown that focusing of the ion beam can improve the stability of the ion current generation and reduces the variation to 18%-20%. In order to find out the reason for the shot-to-shot variation in ion current density we examined the statistical correlation between the current density of the accelerated beam and other measured characteristics of the diode, such as the accelerating voltage, total current, and first pulse duration. The correlation between the ion current density measured simultaneously at different positions within the cross-section of the beam was also investigated. It was shown that the shot-to-shot variation in ion current density is mainly attributed to the variation in the density of electrons diffusing from the drift region into the A-K gap.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.