BackgroundMalignant Ascites (MA) is a therapeutic dilemma significantly impairing patients’ quality of life (QoL). The Sequana Medical alfapump System (AP), a subcutaneous, externally rechargeable, implantable device, continually draining ascites via the urinary bladder, has been well established in liver cirrhosis, but not yet in MA. The AP-system was evaluated in cancer patients in reducing the need for large volume paracentesis (LVP).MethodsA retrospective multicentre evaluation of all eligible patients who received an AP for MA-palliation was performed. AP was evaluated for its ability to reduce LVP and cross-correlated with adverse events (AE), survival and retrospective physician-reported QoL.ResultsSeventeen patients with median age of 63 years (range: 18–81), 70.6% female, across 7 primary tumour types were analysed. Median duration of AP-implantation was 60 min (range: 30–270) and median post-implantation hospital stay: 4 days (range: 2–24). Twelve protocol-defined AE occurred in 5 patients (29.4%): 4 kidney failures, 4 pump/catheter-related blockages, 3 infections/peritonitis and 1 wound dehiscence. Median ascitic volume (AV) pumped daily was 303.6 ml/day (range:5.6–989.3) and median total AV drained was 28 L (range: 1–638.6). Median patient post-AP-survival was 111 days (range:10–715) and median pump survival was 89 days (range: 0–715). Median number of paracenteses was 4 (range: 1–15) per patient pre-implant versus 1 (range: 0–1) post-implant (p = 0.005). 71% of patients were reported to have an improvement of at least one physician reported QoL-parameters.ConclusionsAP appears to be effective in palliating patients with MA by an acceptable morbidity profile. Its broader implementation in oncology services should be further explored.Trial registrationNCT03200106; June 27, 2017.
The early and definitive diagnosis of malignant bile duct stenoses is essential for a timely and adequate therapy. However, tissue sampling with transpapillary brush cytology (BC) or forceps biopsy (FB) remains challenging. With this study, we aimed to compare the effectiveness and safety of different tissue sampling modalities (BC, FB without/after previous balloon dilatation). Standardized database research identified all patients, who underwent endoscopic retrograde cholangiography with BC and/or FB for indeterminate bile duct stenosis between January 2010 and April 2018 and with a definitive diagnosis. 218 patients were enrolled (149 cases with malignant and 69 with benign disease). FB had a significant higher sensitivity than BC (43% vs. 16%, p < 0.01). Prior balloon dilatation of the stenosis improved the sensitivity of FB from 41 to 71% (p = 0.03), the NPV from 36 to 81% (p < 0.01) and the accuracy from 55 to 87% (p < 0.01). The complication rates did not differ significantly between the modalities. In our center FB turned out to be the diagnostically more effective procedure. Balloon dilatation of the stenosis before FB had a significant diagnostic benefit and was not associated with a higher complication rate.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.