a b s t r a c tTo satisfy the requirements of the next generation of dark matter detectors based on the dual phase TPC, Hamamatsu, in close collaboration with UCLA, has developed the R11410-10 photomultiplier tube. In this work, we present the detailed tests performed on this device. High QE ( $ 30%) accompanied by a low dark count rate (50 Hz at 0.3 PE) and high gain (1 Â 10 7 ) with good single PE resolution have been observed. A comprehensive screening measurement campaign is ongoing while the manufacturer quotes a radioactivity of 20 mBq/PMT. These characteristics show the R11410-10 to be particularly suitable for the forthcoming zero background liquid xenon detectors.
Recent studies of the performance of radio-frequency (rf) copper cavities operated at cryogenic temperatures have shown a dramatic increase in the maximum achievable surface electric field. We propose to exploit this development to enable a new generation of photoinjectors operated at cryogenic temperatures that may attain, through enhancement of the launch field at the photocathode, a significant increase in fivedimensional electron beam brightness. We present detailed studies of the beam dynamics associated with such a system, by examining an S-band photoinjector operated at 250 MV=m peak electric field that reaches normalized emittances in the 40 nm-rad range at charges (100-200 pC) suitable for use in a hard x-ray free-electron laser (XFEL) scenario based on the LCLS. In this case, we show by start-to-end simulations that the properties of this source may give rise to high efficiency operation of an XFEL, and permit extension of the photon energy reach by an order of magnitude, to over 80 keV. The brightness needed for such XFELs is achieved through low source emittances in tandem with high current after compression. In the XFEL examples analyzed, the emittances during final compression are preserved using microbunching techniques. Extreme low emittance scenarios obtained at pC charge, appropriate for significantly extending temporal resolution limits of ultrafast electron diffraction and microscopy experiments, are also reviewed. While the increase in brightness in a cryogenic photoinjector is mainly due to the augmentation of the emission current density via field enhancement, further possible increases in performance arising from lowering the intrinsic cathode emittance in cryogenic operation are also analyzed. Issues in experimental implementation, including cavity optimization for lowering cryogenic thermal dissipation, external coupling, and cryocooler system, are discussed. We identify future directions in ultrahigh field cryogenic photoinjectors, including scaling to higher frequency, use of novel rf structures, and enabling of an extremely compact hard x-ray FEL.
Vacuum radio-frequency (rf) breakdown is one of the major factors that limit operating accelerating gradients in rf particle accelerators. The occurrence of rf breakdowns was shown to be probabilistic, and can be characterized by a breakdown rate. Experiments with hard copper cavities showed that harder materials can reach larger accelerating gradients for the same breakdown rate. We study the effect of cavity material on rf breakdowns with short X-band standing wave accelerating structures. Here we report results from tests of a structure at cryogenic temperatures. At gradients greater than 150 MV=m we observed a degradation in the intrinsic cavity quality factor, Q 0. This decrease in Q 0 is consistent with rf power being absorbed by field emission currents, and is accounted for in the determination of accelerating gradients. The structure was conditioned up to an accelerating gradient of 250 MV=m at 45 K with 10 8 rf pulses and a breakdown rate of 2 × 10 −4 =pulse=m. For this breakdown rate, the cryogenic structure has the largest reported accelerating gradient. This improved performance over room temperatures structures supports the hypothesis that breakdown rate can be reduced by immobilizing crystal defects and decreasing thermally induced stresses.
Recent investigations of RF copper structures operated at cryogenic temperatures performed by a SLAC-UCLA collaboration have shown a dramatic increase in the maximum surface electric field, to 500 MV/m. We examine use of these fields to enable very high field cryogenic photoinjectors that can attain over an order of magnitude increase in peak electron beam brightness. We present beam dynamics studies relevant to X-ray FEL injectors, using start-to-end simulations that show the high brightness and low emittance of this source enables operation of a compact FEL reaching a photon energy of 80 keV. The preservation of beam brightness in compression, exploiting microbunching techniques is discussed. While the gain in brightness at high field is due to increase of the emission current density, further increases in brightness due to lowering of the intrinsic cathode emittance in cryogenic operation are also enabled. While the original proposal for this type of cryogenic, ultra-high field photoinjector has emphasized S-band designs, there are numerous potential advantages that may be conferred by operation in C-band. We examine issues related to experimental implementation in C-band, and expected performance of this type of device in a future hard X-ray FEL such as MaRIE.
The development of high brightness electron sources can enable an increase in performance and reduction in size of extreme X-ray sources such as free electron lasers (FELs). A promising path to high brightness is through larger electric fields in radio-frequency (rf) photoinjectors. Recent experiments with 11.4 GHz copper accelerating cavities at cryogenic temperatures have demonstrated 500 MV=m surface electric fields with low rf breakdown rates. However, when the surface electric fields are larger than 300 MV=m, the measured cavity quality factor, Q 0 , decreases during the input rf pulse by up to 30%, recovering before the next rf pulse. In this paper, we present an experimental study of the rf losses, manifested as degradation of Q 0 , in a copper cavity operated at cryogenic temperatures and high gradients. The experimental conditions range from temperatures of 10-77 K and rf pulse lengths of 100-800 ns, using surface electric fields up to 400 MV=m. We developed a model for the change in Q 0 using measured field emission currents and rf signals. We find that the Q 0 degradation is consistent with the rf power being absorbed by strong field emission currents accelerated inside the cavity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.