2023
DOI: 10.1039/d2cc06568a
|View full text |Cite
|
Sign up to set email alerts
|

γ-Glutamyltranspeptidase and pH based “AND” logic gate fluorescent probe for orthotopic breast tumor imaging

Abstract: An “AND” logic gate-based NIR fluorescence probe Si-NH2-Glu was developed based on novel meso-amine Si-Rhodamine, which combined γ-glutamyl transpeptidase and pH dual-responsive sites. The feature of Si-NH2-Glu enable it to...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 27 publications
0
5
0
Order By: Relevance
“…At the cell level, we carry out studies. Based on reported experience, these three amino-substituted probes can target lysosomes, , so we used HepG2 to explore their ability of subcellular localization properties by confocal microscopy. Initially, the cytotoxic properties of the three probes on HepG2 cells were investigated using the CCK-8 assays method through the incubation of different concentrations of these from 0 to 10 μM for 24 h (Figure S11 in the Supporting Information).…”
Section: Resultsmentioning
confidence: 99%
“…At the cell level, we carry out studies. Based on reported experience, these three amino-substituted probes can target lysosomes, , so we used HepG2 to explore their ability of subcellular localization properties by confocal microscopy. Initially, the cytotoxic properties of the three probes on HepG2 cells were investigated using the CCK-8 assays method through the incubation of different concentrations of these from 0 to 10 μM for 24 h (Figure S11 in the Supporting Information).…”
Section: Resultsmentioning
confidence: 99%
“…Meanwhile, Yu and colleagues developed a new NIR fluorescent probe in 2023 ( 13 , Si-NH 2 -Glu) that can be activated in the presence of both GGT and an acid environment in vivo . 39 The probe is comprised of the NIR meso-amine Si–rhodamine as a fluorophore and glutamic acid as a recognition unit for GGT. In the process of probe identification, only in the presence of both GGT and H + is the fluorescence signal at 543 nm of the probe released completely.…”
Section: The Design and Application Of Small-molecule Double-locked L...mentioning
confidence: 99%
“…Another example of a meso-amine Si-rhodamine fluorophore-based responsive probe for GGT measurement represented an interesting "AND" logic gate approach (Figure 12). 60 In this probe (Si-NH 2 -Glu, Probe #18), glutamic acid was incorporated into the Si-NH 2 fluorophore through the typical γglutamyl linker. Interestingly, the NIR emission at 654 nm (λ ex = 515 nm) could be observed after GGT-catalyzed cleavage of γ-glutamyl linker at pH < 7.4.…”
Section: Near-infrared (Nir) Fluorescence Probe For Ggt Measurementmentioning
confidence: 99%