2017
DOI: 10.1039/c6sc05059j
|View full text |Cite
|
Sign up to set email alerts
|

Zwitterionic near infrared fluorescent agents for noninvasive real-time transcutaneous assessment of kidney function

Abstract: Zwitterionic near infrared fluorescent agents were developed for non-invasive real-time transcutaneous assessment of kidney function.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
29
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 30 publications
(30 citation statements)
references
References 39 publications
1
29
0
Order By: Relevance
“…Plasma clearance curves of AAZWCY–HPβCD: c) in the absence of any treatment, d) in the presence of probenecid, and e) in the presence of cimetidine by transcutaneous measurements in healthy rats. f) Clearance half‐lives of ABZWCY–HPβCD and AAZWCY–HPβCD in the absence and presence of probenecid or cimetidine treatment . Reprinted with permission from Ref.…”
Section: Organic Fluorescent Agents For Noninvasive Assessment Of Kidmentioning
confidence: 58%
See 4 more Smart Citations
“…Plasma clearance curves of AAZWCY–HPβCD: c) in the absence of any treatment, d) in the presence of probenecid, and e) in the presence of cimetidine by transcutaneous measurements in healthy rats. f) Clearance half‐lives of ABZWCY–HPβCD and AAZWCY–HPβCD in the absence and presence of probenecid or cimetidine treatment . Reprinted with permission from Ref.…”
Section: Organic Fluorescent Agents For Noninvasive Assessment Of Kidmentioning
confidence: 58%
“…One of the major obstacles encountered with noninvasive real‐time transcutaneous assessment of kidney function in vivo upon using the aforementioned fluorescent GFR agents is strong intrinsic background autofluorescence from living tissue because of their short emission wavelength in the blue and green regions of the spectrum ( λ <600 nm), which significantly compromises the accuracy of the measurements under physiological conditions. However, the absorption coefficient of tissue in the near‐infrared (NIR) region ( λ =650–900 nm) is greatly suppressed to a minimum level, which thus drastically reduces the disturbances and noise from autofluorescence and increases tissue penetration . Therefore, it is highly desirable to develop GFR agents in the NIR optical window for transcutaneous assessment of kidney function.…”
Section: Organic Fluorescent Agents For Noninvasive Assessment Of Kidmentioning
confidence: 99%
See 3 more Smart Citations