1976
DOI: 10.1007/bf00424406
|View full text |Cite
|
Sign up to set email alerts
|

Zur Hochdruck-Fl�ssigkeits-Chromatographie von polycyclischen aromatischen Kohlenwasserstoffen

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
3
0

Year Published

1977
1977
1995
1995

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(3 citation statements)
references
References 3 publications
0
3
0
Order By: Relevance
“…Goldstein reported that polyvinylpyrrolidone) separated PAHs according to the degree of aromaticity and also according to the manner of aromatic ring condensation. This kind of selectivity is quite unique in comparison to the selectivity of both silica (19,20) and octadecyl bonded phases (21,22), whose retention characteristics are affected by aliphatic substituents. Wise et al recently reported the separation of PAHs on a chemically bonded microparticulate amino phase (23).…”
mentioning
confidence: 96%
“…Goldstein reported that polyvinylpyrrolidone) separated PAHs according to the degree of aromaticity and also according to the manner of aromatic ring condensation. This kind of selectivity is quite unique in comparison to the selectivity of both silica (19,20) and octadecyl bonded phases (21,22), whose retention characteristics are affected by aliphatic substituents. Wise et al recently reported the separation of PAHs on a chemically bonded microparticulate amino phase (23).…”
mentioning
confidence: 96%
“…From the theoretical point of view, high-performance liquid chromatography (HPLC) is the best method for analyzing high boiling substances. Thoms and Blümer were successful in separating PAH of molecular weights up to 598 in a test mixture (9,10) and, under the same conditions, in coal tar (11,12). Recently, Peaden et al (13) separated PAH in the molecular weight range from 202 to 448 in carbon black, using reversed-phase C18 columns.…”
mentioning
confidence: 91%
“…FD ionization of benzo[a] pyrene/DNA adducts has been shown to produce sufficient ion beam for MS/MS analysis by B/E linked scans (8). A method of analysis of mixtures of surfactants has been developed recently which makes use of FD ionization and MS/MS analysis with a tandem magnetic sector instrument equipped with a channeltron electron multiplier array (CEMA) detector (9). The instrument permits simultaneous detection of small portions of the CID spectrum which is a real advantage for study of the weak, short-lived, and often fluctuating ion currents produced by…”
mentioning
confidence: 99%