1999
DOI: 10.1016/s0013-4686(99)00146-2
|View full text |Cite
|
Sign up to set email alerts
|

Zinc corrosion in simulated acid rain

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
25
0
2

Year Published

2005
2005
2016
2016

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 47 publications
(30 citation statements)
references
References 26 publications
3
25
0
2
Order By: Relevance
“…The treatment's objective was to simulate atmospheric corrosion as in the working environment of the wall and roof panel system. The specimen was immersed in SAR solution for an hour, and was removed from the solution then allowed to dry in open air environment with exposure to sunlight for 7 hours a day [10][11][12][13][14]. Figure 3 shows a specimen which is immersed in the SAR solution and allowed to be died in open-air environment.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The treatment's objective was to simulate atmospheric corrosion as in the working environment of the wall and roof panel system. The specimen was immersed in SAR solution for an hour, and was removed from the solution then allowed to dry in open air environment with exposure to sunlight for 7 hours a day [10][11][12][13][14]. Figure 3 shows a specimen which is immersed in the SAR solution and allowed to be died in open-air environment.…”
Section: Methodsmentioning
confidence: 99%
“…Recently, the AC impedance technique or EIS method could be used to study an intrusion of water and ions into organic coatings for comparing performance of various inorganic coatings or surface treatments. The EIS method could also be produced models of the solution/inorganic coating/metal system and thus yield mechanistic information about the protective system [10][11][12][13][14].…”
Section: Introductionmentioning
confidence: 99%
“…El mismo comportamiento poseen los metales puros estudiados. Para el caso del zinc esta característica concuerda con lo que concluyó MAGAINO et al [9], ya que para el primer día de inmersión el pH de la solución de lluvia ácida simulada poseía valores aproximados a 3. MAGAINO et al [9] investigaron el comportamiento del zinc puro en una solución de lluvia ácida simulada y llegaron a la conclusión de que la velocidad de corrosión del zinc aumenta drásticamente para valores de pH aproximados a 3.…”
Section: Pérdida De Masa Por Inmersión Y Velocidad De Corrosiónunclassified
“…Uno de sus usos más frecuentes es el galvanizado para exteriores, el cual se encuentra afectado por la corrosión causada por la lluvia ácida, presentado en [8][9][10]. La lluvia no solamente moja la superficie metálica y aporta los electrolitos que provocan la corrosión, sino que también se encarga de renovar constantemente a los electrolitos presentes y lavar los productos de la disolución del metal.…”
Section: Introductionunclassified
“…2 were prepared using de-ionized water and analytical grade reagents [9]. The pH value of the solutions was adjusted to 3.5 and 4.5 using sulfuric acid and potassium hydroxide to simulate the acidic and nearly acidic rain respectively.…”
Section: Specimen Preparationmentioning
confidence: 99%