2012
DOI: 10.2172/1054191
|View full text |Cite
|
Sign up to set email alerts
|

Zgoubi users guide

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 21 publications
(15 reference statements)
0
5
0
Order By: Relevance
“…In a next phase more realistic simulations have been performed by 3D particle tracking in Magnetic fields, which have been calculated using extrapolations from a very simple magnet model (see figure 5). Using POISSON SUPERFISH (Menzel and Stokes 1987) and ZGOUBI (Meot 2012), a 3D map of the magnetic field has been generated. This method ensured us to obtain realistically shaped magnetic fields that obey Maxwell's equations.…”
Section: Magnetic Field Mapmentioning
confidence: 99%
“…In a next phase more realistic simulations have been performed by 3D particle tracking in Magnetic fields, which have been calculated using extrapolations from a very simple magnet model (see figure 5). Using POISSON SUPERFISH (Menzel and Stokes 1987) and ZGOUBI (Meot 2012), a 3D map of the magnetic field has been generated. This method ensured us to obtain realistically shaped magnetic fields that obey Maxwell's equations.…”
Section: Magnetic Field Mapmentioning
confidence: 99%
“…A detailed investigation of the acceptance of the spectrometer has been reported in our earlier work where it was shown that the transmission of the particles through VAMOS is non-uniform and varies within the accepted range of angles and momenta [2]. The study of the transmission was performed by tracing the particles through the magnetic fields using the ion optical code ZGOUBI [16] (the various physical constraints imposed by the apertures of the magnets and detector windows are incorporated into the Figure 2. Two dimensional plot of θ as function of relative rigidity for transmitted particles for two positions of the existing detection system (400 mm × 110 mm).…”
Section: Limitation In the Acceptance And Need For A Larger Area Detementioning
confidence: 99%
“…Different methods of field expansion out of a 2D plane have been used in particle tracking codes. For example, Zgoubi [5] uses Taylor expansion with curl and divergence of the magnetic field being zero in cartesian coordinates.…”
Section: Introductionmentioning
confidence: 99%