1999
DOI: 10.1088/0029-5515/39/9y/306
|View full text |Cite
|
Sign up to set email alerts
|

Z pinch driven inertial confinement fusion target physics research at Sandia National Laboratories

Abstract: Three hohlraum concepts are being pursued at Sandia National Laboratories (SNL) to investigate the possibility of using pulsed power driven magnetic implosions (z-pinches) to drive high gain targets capable of yields in the range of 200-1000 MJ. This research is being conducted on SNL's.2 facility that is capable of driving peak currents of 20 MA in z-pinch loads producing implosion velocities as high as 7.5X107 crn/s, x-ray energies approaching 2 MJ, and x-ray powers exceeding 200 TW. This paper will discuss … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

2
15
0

Year Published

2001
2001
2019
2019

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 71 publications
(17 citation statements)
references
References 14 publications
2
15
0
Order By: Relevance
“…These quantities might be obtained, for example, with an x-ray-framing camera [93]. It has been proposed [34,46,75,80] The quantities f~, fW, T~4, TW4, and (T~/TW)4might be obtained from an x-ray framing camera [93] and a filtered array of x-ray detectors, as described in [64,83]. According to Eqs.…”
Section: T (Xw and Qc-in Terms Of Directly-measurable Quantitiesmentioning
confidence: 99%
See 1 more Smart Citation
“…These quantities might be obtained, for example, with an x-ray-framing camera [93]. It has been proposed [34,46,75,80] The quantities f~, fW, T~4, TW4, and (T~/TW)4might be obtained from an x-ray framing camera [93] and a filtered array of x-ray detectors, as described in [64,83]. According to Eqs.…”
Section: T (Xw and Qc-in Terms Of Directly-measurable Quantitiesmentioning
confidence: 99%
“…In some ICF concepts involving heavy-ion beams or z-pinches, direct radiation from sources located at both ends of a cylindrical hohlraum is blocked from the capsule by polar x-ray symmetrization shields [32,49,54,55,64,66].…”
Section: The Source Indirectly Radiates the Capsulementioning
confidence: 99%
“…The compressed fuel ρr obtained from the n li δr product was 9 mg/cm 2 , under the assumption that the Ar concentration was preserved. The values obtained from the frame 2 data were n e~3 .2 + 0.4 x10 23 cm -3 , ρ~0.86 g/cm 3 , and ρr~5 mg/cm 2 . The n li δr values lead to Ar line center optical depths of τ~50-100 for the Heα and Lyα, τ~ 3 for the Heβ and Lyβ, and τ ~ 0.3 -1.0 for the Heγ and Lyγ lines.…”
mentioning
confidence: 89%
“…The experiments used the Z facility [2,3] to drive a ZPDH configuration [3,5,8] composed of concentric annular tungsten wire arrays with a 240-wire 40-mm-diameter outer array and a 120-wire 20-mm-diameter inner array. The wire diameter was 7.5 µm.…”
mentioning
confidence: 99%
See 1 more Smart Citation