Y2(Ge,Si)O5:Pr phosphors: multimodal temperature and pressure sensors shaped by bandgap management

Abstract: Deliberate managing of luminescent parameters for precise measurements of the two physical quantities executed by the bandgap engineering varying Ge:Si proportion in the Y2(Gex,Si1-x)O5:Pr phosphor.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

5
2

Authors

Journals

citations
Cited by 15 publications
(7 citation statements)
references
References 81 publications
0
4
0
Order By: Relevance
“…The data can be found in the references (indicated by doi number). [ 14,15,44–53 ] In all cases, the pressure sensitivity of the developed sensor in this work corresponds to the highest achievable value for all reported pressure sensor material.…”
Section: Resultsmentioning
confidence: 68%
“…The data can be found in the references (indicated by doi number). [ 14,15,44–53 ] In all cases, the pressure sensitivity of the developed sensor in this work corresponds to the highest achievable value for all reported pressure sensor material.…”
Section: Resultsmentioning
confidence: 68%
“…Moreover, the broadband nature of the emission introduces a potential source of imprecision when Figure 8. Pressure-dependent maximum of the emission band associated with the 4 T 2g → 4 A 2g transition of Cr 3+ ions in doped Li 3 Sc 2 (PO 4 ) 3 (1% Cr 3+ ), with the pressure range defined as the operating range, where a linear dependence of the band centroid as a function of pressure was obtained a); A summary of the most sensitive luminescence manometers in terms of pressure-induced spectral shift rate of the emission band (>1 nm GPa −1 ) b) [6,8,14,37,[43][44][45][46][47][48][49][50][51][52][53][54][55][56] and a d𝜆/dp versus d𝜆/dT plot for representative luminescence manometers based on the spectral shift-c).…”
Section: Resultsmentioning
confidence: 99%
“…This is a very high value comparable to the most sensitive luminescence manometers based on the spectral analysis of materials doped with Ln 3+ ions. 41,42 However, it should be borne in mind that luminescence kinetics is hardly affected by the dispersive dependence of light absorption and scattering by the medium, and therefore allows for a more reliable measurement as proven for luminescence thermometry. 43 In the case of luminescence manometers, it is essential to provide a temperature-invariant pressure readout.…”
Section: Resultsmentioning
confidence: 99%