2008
DOI: 10.1016/j.nima.2008.03.047
|View full text |Cite
|
Sign up to set email alerts
|

XPAD3-S: A fast hybrid pixel readout chip for X-ray synchrotron facilities

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
27
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
5
2
2

Relationship

1
8

Authors

Journals

citations
Cited by 61 publications
(27 citation statements)
references
References 5 publications
0
27
0
Order By: Relevance
“…Currently both fields, silicon photodiodes and CMOS technology, are experiencing considerable improvements which are leading to an increase in detector performance. New generations have also emerged in other families of hybrid pixel detectors, such as Pilatus II [2] and XPAD3 [3], [4]. The advantages of these new photon-counting detectors were quickly appreciated in scattering experiments.…”
mentioning
confidence: 99%
“…Currently both fields, silicon photodiodes and CMOS technology, are experiencing considerable improvements which are leading to an increase in detector performance. New generations have also emerged in other families of hybrid pixel detectors, such as Pilatus II [2] and XPAD3 [3], [4]. The advantages of these new photon-counting detectors were quickly appreciated in scattering experiments.…”
mentioning
confidence: 99%
“…Because photon counting avoids integration of dark noise, very low photon count rates can be acquired with pure Poisson statistics. This has been demonstrated for the camera XPAD3, which can acquire data within a wide range of count rates from 0 to 10 6 photons/pixel/s [3].…”
Section: Methodsmentioning
confidence: 99%
“…YBRID pixel cameras constitute a new generation of digital X-rays detectors [1]- [3]. Instead of integrating the charge generated by the overall incident X-ray flux, hybrid pixels proceed with individual photon counting.…”
Section: Introductionmentioning
confidence: 99%
“…Similarly, improved imaging is expected for modern medical X-ray imagers based on photon counting instead of charge integration [1], both in terms of better contrasts between soft tissues and lower dose exposure. XPAD (X-ray Pixel chip with Adaptable Dynamics) circuits have been developed to meeting these requirements especially for fast readout, accurate energy selection, and high count rate capability [2]. To obtain large sensitive surface, we have designed a new hybrid pixel detector composed of several tens of single XPAD hybrid pixel circuits.…”
Section: Introductionmentioning
confidence: 99%