Xenon-133 inhalation method for regional cerebral blood flow measurements: normal values and test-retest results.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
0
1

Year Published

1982
1982
2021
2021

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 37 publications
(14 citation statements)
references
References 17 publications
0
13
0
1
Order By: Relevance
“…However, adjustment for pCO 2 was not performed because it is not agreed upon by many authors for 133 Xe CBF measurements when the patient is in resting condition [26][27][28]. Moreover, it has been shown that such a correction could even worsen data distribution [27].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, adjustment for pCO 2 was not performed because it is not agreed upon by many authors for 133 Xe CBF measurements when the patient is in resting condition [26][27][28]. Moreover, it has been shown that such a correction could even worsen data distribution [27].…”
Section: Discussionmentioning
confidence: 99%
“…Expired end-tidal pCO 2 was continuously monitored during the examination by a capnograph. All subjects were normocapnic, and ISI values were not corrected for individual pCO 2 values, as suggested by other authors when rCBF examination is performed at rest and in the condition of physiological breathing [26][27][28]. For the present investigation, the absolute ISI value of three probes of the 16-per-hemisphere device (Novo, Hadsund, Denmark), i.e.…”
Section: Patientsmentioning
confidence: 99%
“…rCBF measured by I-123-IMP was considered as standard in this investigation because rCBF measured by I-123-IMP showed good correlation with that of radioactive microspheres or Xe-133 studies [1,2,3,4,5]. However, spatial resolution of SPECT images is lower than that of MR images, and due to this advantage of unique spatial resolution, new MR sequences are being developed to measure cerebral perfusion along with its anatomic details.…”
Section: Discussionmentioning
confidence: 99%
“…Moreover, measurement of regional cerebral blood flow (rCBF) by various brain imaging agents in nuclear medicine techniques has shown good correlation with the gold standard of rCBF measurement either by radioactive microspheres or xenon-133 (Xe-133) studies [1,2,3,4,5]. Measurement of rCBF by iodine-123-iodoamphitamin (I-123-IMP) using auto radiographic (ARG) and modified ARG (table look-up method) have shown very good correlation with the PET, microspheric assessment of cerebral blood flow, and Xe-133 studies [3,6,7,8].…”
mentioning
confidence: 99%
“…Die Ejektionsfraktion war bei allen Normalpersonen > 50%. Nach 5%-iger CO 2 -Inhalation steigt die Hirndurchblutung bei Normalpersonen in der Regel um 10-25% (16,17); in dieser Serie wurden keine neuen CBF-Daten bei CO 2 -Inhalation erhoben.…”
Section: Ergebnisseunclassified