2010
DOI: 10.1093/bioinformatics/btq031
|View full text |Cite
|
Sign up to set email alerts
|

XDIA: improving on the label-free data-independent analysis

Abstract: Supplementary data are available at Bioinformatics online.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
64
0
1

Year Published

2012
2012
2017
2017

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 88 publications
(66 citation statements)
references
References 5 publications
1
64
0
1
Order By: Relevance
“…Those methods operate via unbiased "data-independent acquisition" (DIA), in the cyclic recording, throughout the LC time range, of consecutive survey scans and fragment ion spectra for all the precursors contained in predetermined isolation windows. Various implementations of DIA methods have already been described using isolation windows of various widths, ranging from the complete m/z range to few Daltons (17)(18)(19)(20)(21)(22)(23)(24) (Table I). Using such scans, the link between the fragment ions and the precursors from which they originate is lost, complicating the analysis of the acquired data sets.…”
Section: Liquid Chromatography Coupled To Tandem Mass Spectrometry (Lmentioning
confidence: 99%
See 1 more Smart Citation
“…Those methods operate via unbiased "data-independent acquisition" (DIA), in the cyclic recording, throughout the LC time range, of consecutive survey scans and fragment ion spectra for all the precursors contained in predetermined isolation windows. Various implementations of DIA methods have already been described using isolation windows of various widths, ranging from the complete m/z range to few Daltons (17)(18)(19)(20)(21)(22)(23)(24) (Table I). Using such scans, the link between the fragment ions and the precursors from which they originate is lost, complicating the analysis of the acquired data sets.…”
Section: Liquid Chromatography Coupled To Tandem Mass Spectrometry (Lmentioning
confidence: 99%
“…1B). Similar to other windowed DIA methods (20,23), consecutive swaths were acquired with some precursor isolation window overlap to ensure the transfer of the complete isotopic pattern of any given precursor ion in at least one isolation window and to thereby maintain optimal correlation between parent and fragment isotopes peaks at any LC time point (supplemental Fig. S1, a-f).…”
Section: Data-independent Data Acquisitionmentioning
confidence: 99%
“…Thus, they are DIA. DIA, data-independent analysis/acquisition; SWATH, sequential window acquisition of all theoretical mass spectra MS1 and sequential MS2 windowed acquisitions [5]. At the time, windows of 20 m/z overlapping by 1 m/z.…”
Section: Abstract: Data-dependent Analysis / Data-independent Analysismentioning
confidence: 99%
“…Alternatively, spectra deconvolution approaches have been applied to separate co-eluting peptides transmitted through the same mass-isolation window followed by using MS/MS database searching programs for peptide and protein identification. To date, tandem spectra have been deconvoluted by the following procedures: a) matching precursors detected with similar elution time that fall within the mass-isolation window of MS/MS spectra generated -thereby reassigning mass-isolation windows with vast numbers of possible precursor m/z values with accurate mass values; [18] b) eliminating fragment-ions in MS/MS spectra that do not have similar chromatographic behavior (e.g., lift-off, touchdown, or maximum elution time); [19] c) matching fragment-ions with similar elution profiles to precursors with similar elution time that fall within the same isolation window; [20][21] d) a two-stage identification procedure where (b) and (c) are applied and the search results from both rounds of identification are combined. [22] In this study, we assessed sequential windowed precursor acquisition with three isolation window sizes and various precursor ranges in trypsin digests from E. coli on a Sciex 5600+ QTOF to provide an optimized prototype DIA method for maximizing sensitivity in single injection LC-DIA studies.…”
Section: Introductionmentioning
confidence: 99%