“…If bilirubin alone is detected, quantitation is required with a correction to allow for non-haemorrhagic sources, such as influx of protein bound bilirubin across the blood-brain barrier (see below). 20 Measured CSF bilirubin concentration (µmol/litre) = (A453 − A578) × 23, where 578 nm is the wavelength at which oxyhaemoglobin has identical absorbance to its absorbance at 453 nm, and 23 is the extinction coefficient for bilirubin (µmol/litre) at a wavelength of 453 nm.…”
Section: Detection Of Bilirubin Alonementioning
confidence: 99%
“…If bilirubin alone is detected, quantitation is required with a correction to allow for non-haemorrhagic sources, such as influx of protein bound bilirubin across the blood-brain barrier (see below). 20 Measured CSF bilirubin concentration (µmol/litre) = (A453 − A578) × 23, where 578 nm is the wavelength at which oxyhaemoglobin has identical absorbance to its absorbance at 453 nm, and 23 is the extinction coefficient for bilirubin (µmol/litre) at a wavelength of 453 nm.…”