2004
DOI: 10.1021/ac0400820
|View full text |Cite
|
Sign up to set email alerts
|

X-ray Spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2004
2004
2016
2016

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 158 publications
0
6
0
Order By: Relevance
“…The briquettes were stored in a desiccator. Consequently, the concentrations of Pb, Zn, Cu, Mn and Ni in street dust samples were directly measured by wavelength dispersive X-ray fluorescence spectrometry (XRF, PANalytical PW-2403 apparatus), the relative proportions of dust were determined according to methods [20][21][22]. Meanwhile, a series of soil, sediment and rock standards were used to calibrate the application.…”
Section: Sampling and Analytical Proceduresmentioning
confidence: 99%
“…The briquettes were stored in a desiccator. Consequently, the concentrations of Pb, Zn, Cu, Mn and Ni in street dust samples were directly measured by wavelength dispersive X-ray fluorescence spectrometry (XRF, PANalytical PW-2403 apparatus), the relative proportions of dust were determined according to methods [20][21][22]. Meanwhile, a series of soil, sediment and rock standards were used to calibrate the application.…”
Section: Sampling and Analytical Proceduresmentioning
confidence: 99%
“…Weigh 5.0g of milled bus station dusts sample and 2.0g of boric acid and place in the mold, and press into a 32-mm diameter small briquette under 31.5t pressure, and the briquettes were stored in a desiccator. Therefore, the concentrations of Mn, Zn, Pb, Cr, Cu and Ni in bus station dusts samples were directly measured by wavelength dispersive X-ray fluorescence spectrometry (S8 TIGER Brochures, XRF), the relative proportions of dust were determined according to methods (dos Anjos et al 2000;Staloki et al 2004;Huang and li, 2007;Lu et al 2009aLu et al , 2009b. Meanwhile, a series of soil and rock standards were used to calibrate the application.…”
Section: Sampling and Analytical Proceduresmentioning
confidence: 99%
“…The biennial fundamental reviews in Analytical Chemistry contain the following three recent comprehensive reviews on X-ray spectrometry by Török and colleagues (Török et al 1996, Szalóki et al 2000. Klockenkämper et al (1992) provide a review dedicated to Total-reflection X-ray fluorescence spectroscopy (TXRF).…”
Section: X-ray Fluorescence Spectrometrymentioning
confidence: 99%