2021
DOI: 10.1016/j.radphyschem.2021.109437
|View full text |Cite
|
Sign up to set email alerts
|

X-ray spectra and gamma factors from 70 to 120 kV X-ray tube voltages

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(3 citation statements)
references
References 38 publications
0
2
0
Order By: Relevance
“…Tools The research used in this research is an X-ray machine, CR, Imaging Plate (IP), CR scanner, 21-step stepwedge with an additional 1.5 mm thickness for each step, and software program RadiAnt DICOM VIEWER 2020.1 (64 bit). Before conducting the research, the X-ray machine was turned on and a warm-up procedure was carried out with the collimator facing the examination table (Afifi et al, 2020;Campillo-Rivera et al, 2021). The stepwedge is positioned in the middle of the CR cassette by adjusting the collimation to the size of the stepwedge, where the thickest part is placed in the cathode direction and the thinnest part is placed in the anode direction for AHE application (Dahlan, 2011).…”
Section: Methodsmentioning
confidence: 99%
“…Tools The research used in this research is an X-ray machine, CR, Imaging Plate (IP), CR scanner, 21-step stepwedge with an additional 1.5 mm thickness for each step, and software program RadiAnt DICOM VIEWER 2020.1 (64 bit). Before conducting the research, the X-ray machine was turned on and a warm-up procedure was carried out with the collimator facing the examination table (Afifi et al, 2020;Campillo-Rivera et al, 2021). The stepwedge is positioned in the middle of the CR cassette by adjusting the collimation to the size of the stepwedge, where the thickest part is placed in the cathode direction and the thinnest part is placed in the anode direction for AHE application (Dahlan, 2011).…”
Section: Methodsmentioning
confidence: 99%
“…Numerous factors influence the quality of images produced by digital X-ray radiography techniques. Notable amongst these factors are the setup used, the energy level (kilovoltage kV) [27,28], the tube current (mA), the exposure time [29], and the focal spot size of the X-ray tube used for acquisition [30]. Additionally, the detector properties, the calibration procedure, and the material properties of the inspected component could also affect the quality of acquired images.…”
Section: Radiographic Image Qualitymentioning
confidence: 99%
“…Numerous factors influence the quality of images produced by digital X-ray radiography techniques. Notable amongst these factors are the setup used, energy level (kilovoltage kV) [28,29], the tube current (mA), the exposure time [30], and focal spot size of the X-ray tube used for acquisition [31]. Additionally, detector properties, calibration procedure and the material properties of the inspected component could also affect the quality of acquired images.…”
Section: Radiographic Image Qualitymentioning
confidence: 99%