1985
DOI: 10.1007/bf00747239
|View full text |Cite
|
Sign up to set email alerts
|

X-ray spectra and electronic structure of the POCl3 molecule

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
8
0

Year Published

1994
1994
2001
2001

Publication Types

Select...
7

Relationship

6
1

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 22 publications
0
8
0
Order By: Relevance
“…How this crystal is used to obtain the C KR spectrum is described elsewhere. 15 The samples were deposited on copper supports and cooled to liquid nitrogen temperature in the vacuum chamber of the X-ray tube operating with a copper anode (U ) 6 kV, I ) 0.5 A). The nonlinear reflection efficiency of the NH 4 AP crystal analyzer allows the reliable measurement of the KR emission of carbon in the energy region of 285-275 eV.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…How this crystal is used to obtain the C KR spectrum is described elsewhere. 15 The samples were deposited on copper supports and cooled to liquid nitrogen temperature in the vacuum chamber of the X-ray tube operating with a copper anode (U ) 6 kV, I ) 0.5 A). The nonlinear reflection efficiency of the NH 4 AP crystal analyzer allows the reliable measurement of the KR emission of carbon in the energy region of 285-275 eV.…”
Section: Methodsmentioning
confidence: 99%
“…X-ray fluorescence spectra of the samples 1−4 and nontextured polycrystalline graphite were recorded with X-ray spectrometer “Stearat” using a crystal analyzer of ammonium biphthalate (NH 4 AP). How this crystal is used to obtain the C Kα spectrum is described elsewhere . The samples were deposited on copper supports and cooled to liquid nitrogen temperature in the vacuum chamber of the X-ray tube operating with a copper anode ( U = 6 kV, I = 0.5 A).…”
Section: Methodsmentioning
confidence: 99%
“…NAP single crystal was used as a crystal-analyzer. The technique of applying this crystal-analyzer to obtain C Kα spectra is described in ref . Determination accuracy of X-ray band energy was ±0.15 eV.…”
Section: Methodsmentioning
confidence: 99%
“…The X-ray fluorescence spectrum of C 60 F 48 was recorded with a “Stearat” spectrometer using an ammonium biphthalate (NAP) single crystal as a crystal analyzer. This crystal has nonlinear reflection efficiency, which is corrected by the procedure described elsewhere . The sample was deposited on the copper supports and cooled to liquid nitrogen temperature in the vacuum chamber of the X-ray tube with the copper anode ( U = 6 kV, I = 0.5 A).…”
Section: Methodsmentioning
confidence: 99%