2021
DOI: 10.1016/j.foodres.2020.109996
|View full text |Cite
|
Sign up to set email alerts
|

X-Ray microtomography imaging of red lentil puffed snacks: Processing conditions, microstructure and texture

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
14
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(16 citation statements)
references
References 28 publications
2
14
0
Order By: Relevance
“…The optimal scan settings used were source voltage of 40 kV, current of 208 μA, and a rotational angle of 0.2° over 180°. Images were reconstructed using the NRecon software (Ver 1.7.0, Bruker) to create cross‐sectional images with a resolution of ~14 μm/pixel (Guillermic et al, 2021). The image stacks were then segmented using an image analysis algorithm specifically designed to define the boundaries of puffed snack foods in 3D and find an optimal threshold to differentiate their cells from cell walls (Aksoy, 2019).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The optimal scan settings used were source voltage of 40 kV, current of 208 μA, and a rotational angle of 0.2° over 180°. Images were reconstructed using the NRecon software (Ver 1.7.0, Bruker) to create cross‐sectional images with a resolution of ~14 μm/pixel (Guillermic et al, 2021). The image stacks were then segmented using an image analysis algorithm specifically designed to define the boundaries of puffed snack foods in 3D and find an optimal threshold to differentiate their cells from cell walls (Aksoy, 2019).…”
Section: Methodsmentioning
confidence: 99%
“…Representative extrudate images created using volume viewer on FIJI are provided in Figure 1. The analysis procedure followed the protocol described in Guillermic et al (2021), where the BoneJ local thickness plugin (Doube et al, 2010) was used to define the thickness of the cell walls (mean wall thickness) and the size of the cells (mean cell size). The 3D object counter was used to obtain the total void volume within each subsample, as well as the number of separated objects (i.e., number of closed cells).…”
Section: D Microstructurementioning
confidence: 99%
“…In recent years extensive research has been carried out to develop extruded products from legumes [ 6 , 7 ], in most cases blended with cereals [ 1 , 8 , 9 , 10 ]. Specific studies evaluated the effect of extrusion-cooking parameters, such as feed moisture, extrusion temperature, and screw speed on the nutritional [ 11 ], physico-chemical [ 8 , 10 ], textural [ 12 , 13 ], and sensory characteristics [ 14 ] of the final product, also by means of trials directly carried out at industrial level [ 15 ]. However, no studies were carried out on the effect of the die, which determined the shape and size of the finished products during the extrusion of the legumes.…”
Section: Introductionmentioning
confidence: 99%
“…Indeed, the most recent scanners enable the acquisition of large datasets and very accurate three dimensional (3D) reconstructions in a few minutes. Over time, micro-CT has been successfully used in various research areas including electronics, archeology, food industry, geology, and most of all in the biomedical field [1][2][3][4][5][6]. Within the biomedical area, in addition to cardiovascular, orthopedic, and pulmonary analyses [7,8], in the last decade, forensic applications have progressively increased [9].…”
Section: Introductionmentioning
confidence: 99%