1987
DOI: 10.1126/science.3659925
|View full text |Cite
|
Sign up to set email alerts
|

X-Ray Holograms at Improved Resolution: A Study of Zymogen Granules

Abstract: Abstract-2 -It has long been known that x-ray holography offered the possibility of three-dimensional microscopy with resolution higher than the light microscope and with special forms of contrast based on x-ray edges. In principle, the

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
41
1

Year Published

1988
1988
2010
2010

Publication Types

Select...
3
3
1

Relationship

2
5

Authors

Journals

citations
Cited by 112 publications
(42 citation statements)
references
References 9 publications
0
41
1
Order By: Relevance
“…6 nm x-raya, with a toriodal grating monochromator providing temporal coherence and a pinhole to provide spatial coherence. Our reaul ting coherent flux of typically 10 8 photons/ sec [7,9] was more than 100 times larger than that obtained at the NSLS bending 1 ·' magnet beamline U1S [10] . Besides greatly improving both .exposure time and quality, this dramatically inc;reased illumination greatly simplified the photometry (the coherent flux at X17t was sufficient to produce a photoyield of typically 10-10 Amps on an absolutely calibrated aluminum photodiode [11]) and alignment (the coherent x-ray spot was visible when viewed on a phosphor, even with room illumination) of the experiment.…”
contrasting
confidence: 56%
See 3 more Smart Citations
“…6 nm x-raya, with a toriodal grating monochromator providing temporal coherence and a pinhole to provide spatial coherence. Our reaul ting coherent flux of typically 10 8 photons/ sec [7,9] was more than 100 times larger than that obtained at the NSLS bending 1 ·' magnet beamline U1S [10] . Besides greatly improving both .exposure time and quality, this dramatically inc;reased illumination greatly simplified the photometry (the coherent flux at X17t was sufficient to produce a photoyield of typically 10-10 Amps on an absolutely calibrated aluminum photodiode [11]) and alignment (the coherent x-ray spot was visible when viewed on a phosphor, even with room illumination) of the experiment.…”
contrasting
confidence: 56%
“…1 of Ref. (7]) were negligible compared to the 60 p.m pinhole size. · Most of the holograms are of fixed and dried zymogen granules from rat pancreas acinar cells.…”
mentioning
confidence: 85%
See 2 more Smart Citations
“…However, only with the advent of high brightness x-ray lasers and undulators together with the necessary x-ray optics did the promise begin to become a reality. In 1987 the first hologram with sub-micron resolution was achieved using an undulator at Brookhaven 56 and, almost simultaneously in a completely different experiment, a hologram using a flash subnanosecond exposure was produced from the 206A and 209A selenium soft x-ray laser. 57 As with soft x-ray microscopy, the clear advantage of nanosecond x-ray laser sources is in avoiding the problem of blurring of the image due to morion (possibly due to radiation damage) during the exposure.…”
Section: B Soft X-ray Laser Holographmentioning
confidence: 99%