2005
DOI: 10.1134/1.2171722
|View full text |Cite
|
Sign up to set email alerts
|

X-ray detected magnetic resonance at the Fe K-edge in YIG: Forced precession of magnetically polarized orbital components

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
36
0

Year Published

2007
2007
2017
2017

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 41 publications
(36 citation statements)
references
References 13 publications
0
36
0
Order By: Relevance
“…Major opportunities for fundamental studies [193] Other techniques Nuclear resonant scattering Detection Highest spatial resolution currently achievable [194] X-ray-detected ferromagnetic resonance (XFMR) Detection High spatial resolution, access to layer resolution [195][196][197] Electron-magnon scattering approach Detection Suitable for the detection of domain wall position [198,199] and temporal resolution. For spin-wave excitation techniques the efficiency of excitation, its coherency and the wavenumber range are of primary importance [155-157, 159, 160, 163-165, 168-172, 174, 177-189, 191-199].…”
Section: Detectionmentioning
confidence: 99%
“…Major opportunities for fundamental studies [193] Other techniques Nuclear resonant scattering Detection Highest spatial resolution currently achievable [194] X-ray-detected ferromagnetic resonance (XFMR) Detection High spatial resolution, access to layer resolution [195][196][197] Electron-magnon scattering approach Detection Suitable for the detection of domain wall position [198,199] and temporal resolution. For spin-wave excitation techniques the efficiency of excitation, its coherency and the wavenumber range are of primary importance [155-157, 159, 160, 163-165, 168-172, 174, 177-189, 191-199].…”
Section: Detectionmentioning
confidence: 99%
“…Previous XFMR studies can be divided into two distinct categories: phase-resolved measurements 1-3 and time-averaged measurements. [4][5][6] Both types of measurements are generally performed in transmission, although an earlier phaseresolved study was performed in reflection at grazing incidence. 7 Transmission measurements are usually limited to samples grown on substrates such as Si 3 N 4 that are transparent in the soft x-ray regime.…”
mentioning
confidence: 99%
“…For the first time, clear experimental evidence was produced that the forced precession of the orbital magnetization components z could be detected in YIG films at the iron K-edge [1]. The precession of spinpolarized magnetization components induced by charge delocalizations was also detected at the L 2,3 edges of ions such as Y 3+ or La 3+ which are most often given as "diamagnetic" [5].…”
Section: Precession Dynamics Of Z and S Z Up To Thz Pump Frequenciesmentioning
confidence: 95%
“…E ≥ 2 keV) since the beamline optics and instrumentation are fairly different for the two spectral ranges. Actually, XDMR experiments have been reported which used either hard-XMCD [1][2][3][4][5], or soft-XMCD [6][7][8][9][10][11][12][13][14][15]. In this paper, we shall concentrate on XDMR experiments to be performed at the X-ray absorption K-edges of magnetic 3d transition elements, i.e.…”
Section: Magnetic Resonance With Element and Edge Selectivitymentioning
confidence: 98%
See 1 more Smart Citation