1978
DOI: 10.1016/0029-554x(78)90259-8
|View full text |Cite
|
Sign up to set email alerts
|

X-ray curved-crystal monochromator system at the storage ring DCI

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
38
0
3

Year Published

1980
1980
2013
2013

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 128 publications
(42 citation statements)
references
References 3 publications
1
38
0
3
Order By: Relevance
“…The instrument (Depautex et al, 1987) and the data-acquisition system (Bordas et al, 1980;Boulin, Kempf, Koch & McLaughlin, 1986) have already been described. The monochromatic beam is focused in the horizontal direction on to the detector in a focal spot typically 1 mm wide using a bent triangular Ge(ll 1) crystal mounted in the compressive Fankuchen geometry with a cut angle c~ = 10.5 ° (Lemonnier, Fourme, Rousseaux & Kahn, 1978). The wavelength of the X-rays was A = 1.488/~ (Ni absorption K-edge).…”
Section: Methodsmentioning
confidence: 99%
“…The instrument (Depautex et al, 1987) and the data-acquisition system (Bordas et al, 1980;Boulin, Kempf, Koch & McLaughlin, 1986) have already been described. The monochromatic beam is focused in the horizontal direction on to the detector in a focal spot typically 1 mm wide using a bent triangular Ge(ll 1) crystal mounted in the compressive Fankuchen geometry with a cut angle c~ = 10.5 ° (Lemonnier, Fourme, Rousseaux & Kahn, 1978). The wavelength of the X-rays was A = 1.488/~ (Ni absorption K-edge).…”
Section: Methodsmentioning
confidence: 99%
“…To demonstrate conditions under which the above simple description is satisfactory we measured the transmittance as a function of the radius of curvature (controlled by the push tip position) for waveguides made from thin Si(111) wafers, which were Syton polished to a hazefree mirror finish by Virginia Semiconductor, Inc. The waveguides were formed in triangular shapes to achieve approximately constant radius of curvature across the surface [9]. A monochromatic Mo K a x-ray beam from a rotating anode x-ray machine was coupled into the waveguide at a grazing angle (see Fig.…”
mentioning
confidence: 99%
“…This arrangement is based on the commonly used geometry introduced by Lemonnier et al [10] and developed by many groups [for example, see references 11 and 12 and references in 13]. The curved-crystal monochromators will be identical and will have an asymmetric-cut arrangement with a nominal compression factor of 10.…”
Section: Beamline Configurationmentioning
confidence: 99%
“…This movement will obscure the central station position .. In this case, taking into account optical, aberrations, the demagnification and the angular dispersion of the diffracted beam [10], the horizontal image size will be 0.3 mm (FWHM).…”
Section: Beamline Configurationmentioning
confidence: 99%