2020
DOI: 10.1109/access.2020.2971083
|View full text |Cite
|
Sign up to set email alerts
|

Wireless Multi-Hop Energy-Efficient System for High-Density Seismic Array

Abstract: High-density seismic array method has attracted enormous interest in geophysical methods, and it is an advanced seismic observation technology which is of great significance in oil and gas resource detection and underground space exploration. However, designing a portable sensor node that prolongs the lifetime and equips wireless monitoring system to improve construction efficiency has been still a challenge for the high-density seismic array method. In this paper, a portable energy-efficient wireless sensor n… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 14 publications
(3 citation statements)
references
References 25 publications
0
2
0
Order By: Relevance
“…In [29], multi variable weight route selection the algorithm based on the residual energy and distance of the node for high density seismic array is presented. Using spanning tree, a strategy for energy consumption distribution over the CHs by multipath data routing is proposed in [30].…”
Section: Literature Reviewmentioning
confidence: 99%
“…In [29], multi variable weight route selection the algorithm based on the residual energy and distance of the node for high density seismic array is presented. Using spanning tree, a strategy for energy consumption distribution over the CHs by multipath data routing is proposed in [30].…”
Section: Literature Reviewmentioning
confidence: 99%
“…The nodal cable-less storage-type seismic data acquisition system performs long-term, uninterrupted acquisition tasks under the condition of continuous source excitation, which requires the sensor nodes to be always kept synchronized. As the acquisition time increases, the frequency drift of the crystal oscillator on the acquisition station will bring significant time error accumulation [20,21]. The time-synchronization system should be able to continuously correct the time errors that occur to avoid error accumulation.…”
Section: Time-synchronization Requirements For High-density Seismic A...mentioning
confidence: 99%
“…In spite of the increase in research, publishing and development on nodal seismographs, e.g. Hawk, Smart-Solo, WTU-508 (Lv et al, 2022) and others developed by Tian (2020), the wired seismograph system is suitable for certain exploration situations (Ellis, 2014). As is found by Lansley (2012), the best exploration system structure in the near future should be a combination of wired and wireless systems, which could also be provided by the upgrade from the 428XL system to the 508XT system developed by an industry-leading company.…”
Section: Introductionmentioning
confidence: 99%