1998 IEEE MTT-S International Microwave Symposium Digest (Cat. No.98CH36192)
DOI: 10.1109/mwsym.1998.689368
|View full text |Cite
|
Sign up to set email alerts
|

Wideband crossed-guide waveguide directional couplers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 16 publications
(7 citation statements)
references
References 6 publications
0
7
0
Order By: Relevance
“…Simulation result shows that the response is narrowband, with coupling varying more than 15 dB across the full waveguide band. Wideband coupler can be designed using reduced-height waveguide [13]. This paper shows a coupling of 10 dB + 0.8 dB over a bandwidth of 10% can be achieved in crossed-guide coupler using reduced-height waveguide in W band.…”
Section: Introductionmentioning
confidence: 91%
See 1 more Smart Citation
“…Simulation result shows that the response is narrowband, with coupling varying more than 15 dB across the full waveguide band. Wideband coupler can be designed using reduced-height waveguide [13]. This paper shows a coupling of 10 dB + 0.8 dB over a bandwidth of 10% can be achieved in crossed-guide coupler using reduced-height waveguide in W band.…”
Section: Introductionmentioning
confidence: 91%
“…In literature, design data of crossed-guide cross-slot directional coupler is reported upto microwave frequencies [9][10][11][12][13]. Broad-wall metal-insert slot couplers are reported in [14] for millimeter-wave applications, but no design data on waveguide crossed-guide crossed slot coupler at millimeterwave frequency range is reported in standard literature.…”
Section: Introductionmentioning
confidence: 99%
“…no moving parts and the space constraints. To achieve this, a calibration system with a stable pilot signal injected through a directional coupler (Meyer and Kruger, 1998) The 557 GHz horn is an exact scaled version of the 183 GHz horn but no measurements were performed because of the absence of suitable equipment at this frequency. The 557 GHz horn was produced by Radiometric Physics GmbH (Radiometric Physics Gmbh) by electroforming and the horn performance is expected to be the same as for the 183 GHz horn relying on exact scaling effect.…”
Section: The 183 Ghz Rf Channel Calibration Systemmentioning
confidence: 99%
“…Crossed‐waveguide directional couplers are usually used due to their compact structures. Theory analysis of cross‐guide couplers was well studied in the literature . In these structures, the cross‐apertures are employed to offer flat coupling and high isolation.…”
Section: Introductionmentioning
confidence: 99%