2019
DOI: 10.1097/prs.0000000000005379
|View full text |Cite
|
Sign up to set email alerts
|

Wide-Awake Surgical Management of Hand Fractures: Technical Pearls and Advanced Rehabilitation

Abstract: Summary: Most unstable metacarpal and phalangeal fractures for which operative treatment is indicated can be reduced and stabilized with either open or closed techniques using local anesthetic with epinephrine instead of intravenous sedation or general anesthesia. With the patient wide-awake during surgery, the hand can be taken through active range of motion to assess fracture stability. In this article, the authors review the rationale and technique for wide-awake, local anesthesia, no tourniquet… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 20 publications
(7 citation statements)
references
References 31 publications
0
7
0
Order By: Relevance
“…Future areas of research and innovation include performing fixation using lidocaine and epinephrine (in place of general anesthesia) with no tourniquet in "wide-awake" operations. [68][69][70] Some authors claim better intraoperative assessment of fracture stability that facilitates quicker recovery and range-of-motion exercises, minimizing finger stiffness. Research has also been conducted on the use of absorbable plates for displaced finger fractures; however, the quality of evidence is lacking to recommend routine use.…”
Section: Discussionmentioning
confidence: 99%
“…Future areas of research and innovation include performing fixation using lidocaine and epinephrine (in place of general anesthesia) with no tourniquet in "wide-awake" operations. [68][69][70] Some authors claim better intraoperative assessment of fracture stability that facilitates quicker recovery and range-of-motion exercises, minimizing finger stiffness. Research has also been conducted on the use of absorbable plates for displaced finger fractures; however, the quality of evidence is lacking to recommend routine use.…”
Section: Discussionmentioning
confidence: 99%
“…Surgery was performed by 2 experienced hand surgeons of our department. In order to get a better judgment, we use the wide-wake technique for anesthesia that is the fluoroscopy and activity of DIP (or PIP) can be judged during the operation [13] …”
Section: Methodsmentioning
confidence: 99%
“…3,5 Instead, the danger of end-artery organ necrosis that is stigmatized by physicians was previously derived from the preceding local anesthesia, which was the expired procaine, instead of epinephrine. 3,6 In addition, epinephrine has been widely practiced in surgeries for vascular malformation, 7 fractures, 8 hand intrinsic flaps, 9 burn contractures, 10 digital replantation, 11 etc.…”
Section: Historical Perspectivementioning
confidence: 99%