2008
DOI: 10.1063/1.2965010
|View full text |Cite
|
Sign up to set email alerts
|

Wide-angle point-to-point x-ray imaging with almost arbitrarily large angles of incidence

Abstract: The paper describes a new scheme for wide-angle point-to-point x-ray imaging with almost arbitrarily large angles of incidence by a matched pair of spherically bent crystals to eliminate the astigmatism, which is a well-known imaging error of spherical mirrors. In addition to x rays, the scheme should be applicable to a very broad spectrum of the electromagnetic radiation, including microwaves, infrared and visible light, as well as UV and extreme UV radiation, if the crystals are replaced with appropriate sph… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
15
0

Year Published

2008
2008
2023
2023

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 13 publications
(15 citation statements)
references
References 7 publications
0
15
0
Order By: Relevance
“…(6) in Ref. [4], must be satisfied for the rays between the two crystals. Equation (3) is evidently different from Eq.…”
Section: Special Requirements For X Raysmentioning
confidence: 99%
See 2 more Smart Citations
“…(6) in Ref. [4], must be satisfied for the rays between the two crystals. Equation (3) is evidently different from Eq.…”
Section: Special Requirements For X Raysmentioning
confidence: 99%
“…In a previous paper [4] we described an imaging scheme which eliminates astigmatism by the use of two spherically bent crystals or spherical mirrors and thus provides point-to-point imaging with almost arbitrarily large angles of incidence. This imaging scheme can be applied to a broad spectrum of the electromagnetic radiation, including microwaves, infrared and visible light, UV and extreme UV radiation, and x rays; and it may also be applicable to imaging with ultrasound.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The differences reside not only in the spectrometer dimensions and layouts, and the detectors used (to obtain high throughput as well as high time and spatial resolution for the duration of a plasma discharge of several seconds) but also in the fact that the astigmatism of the spherically bent crystal can be used with advantage because of the symmetry due to the toroidal magnetic field and uniformity of the x-ray emission along the toroidal magnetic field. We also present supplementary information on imaging schemes, where the astigmatism has been eliminated by the use of matched pairs of spherically bent crystals or reflectors [13,14]. These imaging schemes, which are still in the early stages of development and testing, should be applicable to a wide spectrum of the electromagnetic radiation.…”
Section: Introductionmentioning
confidence: 99%
“…We have recently proposed different types of imaging schemes, [9][10][11] where the astigmatism can be fully eliminated by the use of two spherically bent crystals (or reflectors), so that stigmatic imaging is possible for almost arbitrary Bragg angles or angles of incidence. In this paper, we describe a new scheme which is related to these earlier schemes and which can provide images with a large magnification.…”
Section: Introductionmentioning
confidence: 99%