2022
DOI: 10.1016/j.compbiomed.2022.105301
|View full text |Cite
|
Sign up to set email alerts
|

Whole slide image registration via multi-stained feature matching

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(6 citation statements)
references
References 37 publications
0
5
0
Order By: Relevance
“…In this study, we adopt Dice Similarity Coefficient (DSC), 53 Hausdorff Distance (HD), 54 SSIM, and NCC for WSI block registration accuracy evaluation. 55 For DSC and HD evaluation, 8 region of interest (ROI) pairs are manually annotated from the testing and validation WSI blocks. The complete evaluation process is presented in Supplemental Figure S7 and the quantitative results are shown in Table 4 .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In this study, we adopt Dice Similarity Coefficient (DSC), 53 Hausdorff Distance (HD), 54 SSIM, and NCC for WSI block registration accuracy evaluation. 55 For DSC and HD evaluation, 8 region of interest (ROI) pairs are manually annotated from the testing and validation WSI blocks. The complete evaluation process is presented in Supplemental Figure S7 and the quantitative results are shown in Table 4 .…”
Section: Resultsmentioning
confidence: 99%
“… 19 Moreover, a modified SIFT method is applied to image registration with color interpolation. 20 WSIReg is another method for WSI registration based on elastix. 21 However, all these methods require feature matching that highly depends on feature engineering and parameter tuning.…”
Section: Introductionmentioning
confidence: 99%
“…After individual image patch registrations, they are spatially assembled to generate the registered WSI blocks. In this study, we adopt Dice Similarity Coefficient (DSC) [38], Hausdorff Distance (HD) [39], SSIM, and NCC for WSI block registration accuracy evaluation [40]. For DSC and HD evaluation, eight Region of Interest (ROI) pairs are manually annotated from the testing and validation WSI blocks.…”
Section: Evaluation Of Wsi Block Registrationmentioning
confidence: 99%
“…In a study on multi-stained histology image registration, a method is developed by the feature-based affine registration, rotation alignment followed by nonrigid alignment with Demons algorithm [4]. Moreover, a modified SIFT method is applied to image registration with color interpolation [5]. WSIReg is another method for WSI registration based on elastix [6].…”
Section: Introductionmentioning
confidence: 99%
“…Although this method has high precision and perfect registration performance, it is relatively time-consuming. Hoque et al 20 proposed an automatic histological image registration, and a joint distance was used to eliminate position transformation error and add match keypoints. And this method has been well applied in the medical field.…”
Section: Introductionmentioning
confidence: 99%